User name adev
Log entry time 03:54:58 on October 2, 2000
Entry number 49013
keyword=Start_Run_1298_Tar=lead-cool,Type=Other,Pmom=0.756,Emom=0.821,Ene=826,Angle_e=14.993,Angle_h=53.768
Beginning-of-run EPICS data for Run Number 1298 at Mon Oct 2 03:54:47 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=300,ps2=10000,ps3=10000,ps4=50000,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 617.365
Right Arm Q1 momentum : 0.821035
Right Arm Q1 gauss meter : -0.015485
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 353.348
Right Arm Q2 momentum : 0.821038
Right Arm Q2 gauss meter : 0.18587
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 282.182
Right Arm D1 momentum : 0.820999
Right Arm D1 NMR : 0.304663
Right Arm Q3 power supply current : 326.869
Right Arm Q3 momentum : 0.821467
Right Arm Q3 gauss meter : 0.14652
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.505
Left Arm Q1 momentum : 0.755658
Left Arm Q1 gauss meter : -0.04813
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.548
Left Arm Q2 momentum : 0.756033
Left Arm Q2 gauss meter : 0.17225
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.11
Left Arm D1 momentum : 0.756003
Left Arm D1 NMR : 0.279956
Left Arm Q3 power supply current : 301.011
Left Arm Q3 momentum : 0.756083
Left Arm Q3 gauss meter : -0.14989
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 1.54574
Current on Unser monitor : 2.14447
Current on Upstream bcm : 1.56363
Current on Downstream bcm : 1.52785
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 1.50167
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 991010
haL1_Fan_frequency_R : 63.5
haL2_Fan_frequency_R : 38
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.27
haSC200_6_Sensor_2_R : 222.02
haSC200_6_Sensor_3_R : -0.13
haSC200_6_Sensor_4_R : 35.59
haHe_Omega_DPG_Sensor_R : 5.738
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.83999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 4.9
haITC502_4_Sensor_3_R : 75.1
haITC502_5_Sensor_1_R : 5.82
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 181.3
haITC502_6_Sensor_1_R : 5.81
haITC502_6_Sensor_2_R : 5.79
haITC502_6_Sensor_3_R : 27.15
Right Arm Arm Collimator : 0.364209
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1346
HacR_VPM_LVDT:VALr : -800
HacR_HPE1313A:0_Ch58 : -0.560547
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.854004
HacR_alignROLL : -0.374285
HacR_alignPITCH : 0.00311622
HacR_alignHPT : -1.26136
HacL_HPM_LVDT:VALr : -7479
HacL_VPM_LVDT:VALr : -667
HacL_HPE1313A:0_Ch58 : -0.316895
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.362305
HacL_alignROLL : 0.00991206
HacL_alignPITCH : 0.0384876
HacL_alignHPT : 4.61893
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -37
Right Arm Scattering Angle : 14.9923
Left Arm Angle Floor Angle : 53.5
Left Arm Angle Vernier : 83
Left Arm Scattering Angle : 53.7681
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 110
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88