Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 05:49:11 on October 2, 2000
Entry number 49032
keyword=Start_Run_1304_Tar=4He-10cm,Type=Elastic,Pmom=0.756,Emom=0.756,Ene=826,Angle_e=53.783,Angle_h=53.768
Beginning-of-run EPICS data for Run Number 1304 at Mon Oct 2 05:49:00 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=10000,ps3=10000,ps4=50000,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 568.54
Right Arm Q1 momentum : 0.756103
Right Arm Q1 gauss meter : -0.014277
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 325.491
Right Arm Q2 momentum : 0.756311
Right Arm Q2 gauss meter : 0.17125
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 263.066
Right Arm D1 momentum : 0.807307
Right Arm D1 NMR : 0.299582
Right Arm Q3 power supply current : 301.011
Right Arm Q3 momentum : 0.756484
Right Arm Q3 gauss meter : 0.13497
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.435
Left Arm Q1 momentum : 0.755564
Left Arm Q1 gauss meter : -0.04816
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.727
Left Arm Q2 momentum : 0.75645
Left Arm Q2 gauss meter : 0.17228
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.114
Left Arm D1 momentum : 0.755999
Left Arm D1 NMR : 0.279955
Left Arm Q3 power supply current : 300.943
Left Arm Q3 momentum : 0.755913
Left Arm Q3 gauss meter : -0.14987
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.14102
Current on Unser monitor : 5.77615
Current on Upstream bcm : 5.20141
Current on Downstream bcm : 5.10448
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.23087
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 50.5
haL2_Fan_frequency_R : 37
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.08
haSC200_6_Sensor_2_R : 223.57
haSC200_6_Sensor_3_R : -0.28
haSC200_6_Sensor_4_R : 35.57
haHe_Omega_DPG_Sensor_R : 5.781
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.84999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 5.2
haITC502_4_Sensor_3_R : 78.5
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 178.2
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.82
haITC502_6_Sensor_3_R : 26.95
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4875
HacR_VPM_LVDT:VALr : 182
HacR_HPE1313A:0_Ch58 : -0.537598
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.818359
HacR_alignROLL : -0.338425
HacR_alignPITCH : -0.0169444
HacR_alignHPT : 2.55127
HacL_HPM_LVDT:VALr : -7491
HacL_VPM_LVDT:VALr : -453
HacL_HPE1313A:0_Ch58 : -0.310059
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.354492
HacL_alignROLL : 0.0177257
HacL_alignPITCH : 0.0316428
HacL_alignHPT : 4.62859
Right Arm Angle Floor Angle : 53.5
Right Arm Angle Vernier : 17.9
Right Arm Scattering Angle : 53.7829
Left Arm Angle Floor Angle : 53.5
Left Arm Angle Vernier : 83
Left Arm Scattering Angle : 53.768
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 180
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88