Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 05:54:41 on October 2, 2000
Entry number 49036
keyword=Start_Run_1306_Tar=4He-10cm,Type=Elastic,Pmom=0.756,Emom=0.756,Ene=826,Angle_e=53.783,Angle_h=53.768
Beginning-of-run EPICS data for Run Number 1306 at Mon Oct 2 05:54:26 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=50000,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 568.61
Right Arm Q1 momentum : 0.756196
Right Arm Q1 gauss meter : -0.014277
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 325.475
Right Arm Q2 momentum : 0.756273
Right Arm Q2 gauss meter : 0.17123
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 244.135
Right Arm D1 momentum : 0.779544
Right Arm D1 NMR : 0.289279
Right Arm Q3 power supply current : 300.841
Right Arm Q3 momentum : 0.756056
Right Arm Q3 gauss meter : 0.13499
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.435
Left Arm Q1 momentum : 0.755564
Left Arm Q1 gauss meter : -0.04814
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.383
Left Arm Q2 momentum : 0.755651
Left Arm Q2 gauss meter : 0.1722
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.113
Left Arm D1 momentum : 0.756001
Left Arm D1 NMR : 0.279956
Left Arm Q3 power supply current : 300.971
Left Arm Q3 momentum : 0.755983
Left Arm Q3 gauss meter : -0.14986
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.16957
Current on Unser monitor : 5.47011
Current on Upstream bcm : 5.22208
Current on Downstream bcm : 5.10805
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.22124
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 64
haL2_Fan_frequency_R : 38
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.1
haSC200_6_Sensor_2_R : 223.77
haSC200_6_Sensor_3_R : -0.27
haSC200_6_Sensor_4_R : 35.55
haHe_Omega_DPG_Sensor_R : 5.689
haITC502_1_Sensor_1_R : 5.81
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.85999
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 5.1
haITC502_4_Sensor_3_R : 78.6
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 178
haITC502_6_Sensor_1_R : 5.82
haITC502_6_Sensor_2_R : 5.82
haITC502_6_Sensor_3_R : 26.93
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4875
HacR_VPM_LVDT:VALr : 189
HacR_HPE1313A:0_Ch58 : -0.537109
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.819336
HacR_alignROLL : -0.340338
HacR_alignPITCH : -0.0174595
HacR_alignHPT : 2.55236
HacL_HPM_LVDT:VALr : -7491
HacL_VPM_LVDT:VALr : -451
HacL_HPE1313A:0_Ch58 : -0.310059
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.353516
HacL_alignROLL : 0.0180986
HacL_alignPITCH : 0.0321497
HacL_alignHPT : 4.62953
Right Arm Angle Floor Angle : 53.5
Right Arm Angle Vernier : 17.9
Right Arm Scattering Angle : 53.7829
Left Arm Angle Floor Angle : 53.5
Left Arm Angle Vernier : 83
Left Arm Scattering Angle : 53.768
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 180
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88