User name adev
Log entry time 06:04:44 on October 2, 2000
Entry number 49038
keyword=Start_Run_1307_Tar=4He-10cm,Type=Elastic,Pmom=0.756,Emom=0.756,Ene=826,Angle_e=53.783,Angle_h=53.768
Beginning-of-run EPICS data for Run Number 1307 at Mon Oct 2 06:04:29 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=50000,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 568.54
Right Arm Q1 momentum : 0.756103
Right Arm Q1 gauss meter : -0.014273
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 325.482
Right Arm Q2 momentum : 0.756288
Right Arm Q2 gauss meter : 0.17128
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 254.197
Right Arm D1 momentum : 0.75594
Right Arm D1 NMR : 0.28052
Right Arm Q3 power supply current : 300.885
Right Arm Q3 momentum : 0.756167
Right Arm Q3 gauss meter : 0.13495
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.4
Left Arm Q1 momentum : 0.755518
Left Arm Q1 gauss meter : -0.04814
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.549
Left Arm Q2 momentum : 0.756036
Left Arm Q2 gauss meter : 0.17232
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.115
Left Arm D1 momentum : 0.755998
Left Arm D1 NMR : 0.279954
Left Arm Q3 power supply current : 301.03
Left Arm Q3 momentum : 0.75613
Left Arm Q3 gauss meter : -0.14989
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.8875
Current on Unser monitor : 41.4132
Current on Upstream bcm : 40.4133
Current on Downstream bcm : 39.464
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 40.311
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 39
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.08
haSC200_6_Sensor_2_R : 225.36
haSC200_6_Sensor_3_R : -0.28
haSC200_6_Sensor_4_R : 35.54
haHe_Omega_DPG_Sensor_R : 5.67
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.92999
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 5.2
haITC502_4_Sensor_3_R : 78.6
haITC502_5_Sensor_1_R : 5.86
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 177.8
haITC502_6_Sensor_1_R : 5.9
haITC502_6_Sensor_2_R : 5.91
haITC502_6_Sensor_3_R : 26.92
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4878
HacR_VPM_LVDT:VALr : 198
HacR_HPE1313A:0_Ch58 : -0.536133
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.820801
HacR_alignROLL : -0.34144
HacR_alignPITCH : -0.0186727
HacR_alignHPT : 2.55622
HacL_HPM_LVDT:VALr : -7492
HacL_VPM_LVDT:VALr : -444
HacL_HPE1313A:0_Ch58 : -0.310547
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.353027
HacL_alignROLL : 0.0175881
HacL_alignPITCH : 0.0330935
HacL_alignHPT : 4.62866
Right Arm Angle Floor Angle :
Right Arm Angle Vernier : 17.9
Right Arm Scattering Angle : 53.7829
Left Arm Angle Floor Angle : 53.5
Left Arm Angle Vernier : 83
Left Arm Scattering Angle : 53.768
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 190
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88