Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 06:44:12 on October 2, 2000
Entry number 49042
keyword=Start_Run_1308_Tar=4He-10cm,Type=Elastic,Pmom=0.756,Emom=0.756,Ene=826,Angle_e=53.783,Angle_h=50.677
Beginning-of-run EPICS data for Run Number 1308 at Mon Oct 2 06:44:01 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=50000,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 568.54
Right Arm Q1 momentum : 0.756103
Right Arm Q1 gauss meter : -0.01427
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 325.453
Right Arm Q2 momentum : 0.756222
Right Arm Q2 gauss meter : 0.17134
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 259.194
Right Arm D1 momentum : 0.756039
Right Arm D1 NMR : 0.280557
Right Arm Q3 power supply current : 300.673
Right Arm Q3 momentum : 0.755633
Right Arm Q3 gauss meter : 0.13496
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.435
Left Arm Q1 momentum : 0.755564
Left Arm Q1 gauss meter : -0.04812
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.592
Left Arm Q2 momentum : 0.755586
Left Arm Q2 gauss meter : 0.17227
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.114
Left Arm D1 momentum : 0.756001
Left Arm D1 NMR : 0.279956
Left Arm Q3 power supply current : 300.953
Left Arm Q3 momentum : 0.755937
Left Arm Q3 gauss meter : -0.14989
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.4251
Current on Unser monitor : 40.4904
Current on Upstream bcm : 39.8767
Current on Downstream bcm : 38.9735
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 39.6939
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 65.5
haL2_Fan_frequency_R : 37
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.06
haSC200_6_Sensor_2_R : 225.47
haSC200_6_Sensor_3_R : -0.28
haSC200_6_Sensor_4_R : 35.54
haHe_Omega_DPG_Sensor_R : 5.689
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.92999
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 5.2
haITC502_4_Sensor_3_R : 78.3
haITC502_5_Sensor_1_R : 5.87
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 177.5
haITC502_6_Sensor_1_R : 5.91
haITC502_6_Sensor_2_R : 5.89
haITC502_6_Sensor_3_R : 26.9
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4903
HacR_VPM_LVDT:VALr : 215
HacR_HPE1313A:0_Ch58 : -0.531738
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.824707
HacR_alignROLL : -0.346252
HacR_alignPITCH : -0.0223956
HacR_alignHPT : 2.58681
HacL_HPM_LVDT:VALr : -8097
HacL_VPM_LVDT:VALr : -722
HacL_HPE1313A:0_Ch58 : -0.305664
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.349609
HacL_alignROLL : 0.0212595
HacL_alignPITCH : 0.0285866
HacL_alignHPT : 5.30401
Right Arm Angle Floor Angle : 53.5
Right Arm Angle Vernier : 17.9
Right Arm Scattering Angle : 53.7826
Left Arm Angle Floor Angle : 50.5
Left Arm Angle Vernier : 68
Left Arm Scattering Angle : 50.677
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 190
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88