Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 07:13:32 on October 2, 2000
Entry number 49045
keyword=Start_Run_1309_Tar=4He-10cm,Type=Elastic,Pmom=0.756,Emom=0.756,Ene=826,Angle_e=53.783,Angle_h=48.72
Beginning-of-run EPICS data for Run Number 1309 at Mon Oct 2 07:13:17 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=50000,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 568.54
Right Arm Q1 momentum : 0.756103
Right Arm Q1 gauss meter : -0.014277
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 325.39
Right Arm Q2 momentum : 0.756075
Right Arm Q2 gauss meter : 0.17122
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 259.202
Right Arm D1 momentum : 0.75604
Right Arm D1 NMR : 0.280557
Right Arm Q3 power supply current : 300.814
Right Arm Q3 momentum : 0.756013
Right Arm Q3 gauss meter : 0.13491
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 568.435
Left Arm Q1 momentum : 0.755564
Left Arm Q1 gauss meter : -0.04812
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 325.494
Left Arm Q2 momentum : 0.755908
Left Arm Q2 gauss meter : 0.17221
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 252.114
Left Arm D1 momentum : 0.756003
Left Arm D1 NMR : 0.279956
Left Arm Q3 power supply current : 301.015
Left Arm Q3 momentum : 0.756094
Left Arm Q3 gauss meter : -0.14988
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.6599
Current on Unser monitor : 40.4846
Current on Upstream bcm : 40.2169
Current on Downstream bcm : 39.103
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 39.9921
Beam energy : 825.959
MBSY1c magnet current (amp) : 34.0388
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 39.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.05
haSC200_6_Sensor_2_R : 225.44
haSC200_6_Sensor_3_R : -0.23
haSC200_6_Sensor_4_R : 35.52
haHe_Omega_DPG_Sensor_R : 5.741
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.93999
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 5.2
haITC502_4_Sensor_3_R : 78.3
haITC502_5_Sensor_1_R : 5.87
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 177.2
haITC502_6_Sensor_1_R : 5.91
haITC502_6_Sensor_2_R : 5.88
haITC502_6_Sensor_3_R : 26.89
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4900
HacR_VPM_LVDT:VALr : 221
HacR_HPE1313A:0_Ch58 : -0.530762
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.827148
HacR_alignROLL : -0.347238
HacR_alignPITCH : -0.0232931
HacR_alignHPT : 2.58626
HacL_HPM_LVDT:VALr : -7345
HacL_VPM_LVDT:VALr : -885
HacL_HPE1313A:0_Ch58 : -0.304688
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.346191
HacL_alignROLL : 0.0242136
HacL_alignPITCH : 0.0278546
HacL_alignHPT : 4.46234
Right Arm Angle Floor Angle : 53.5
Right Arm Angle Vernier : 17.9
Right Arm Scattering Angle : 53.7826
Left Arm Angle Floor Angle : 48.5
Left Arm Angle Vernier : 75
Left Arm Scattering Angle : 48.723
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 190
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88