User name adev
Log entry time 15:16:20 on October 2, 2000
Entry number 49070
keyword=Start_Run_1317_Tar=absence,Type=Cosmic,Pmom=0.756,Emom=0.756,Ene=826,Angle_e=53.783,Angle_h=55.80
Beginning-of-run EPICS data for Run Number 1317 at Mon Oct 2 15:16:09 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=100,ps3=1,ps4=1,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1687.28
Right Arm Q1 momentum : 2.24392
Right Arm Q1 gauss meter : -0.04216
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 965.57
Right Arm Q2 momentum : 2.2436
Right Arm Q2 gauss meter : 0.5077
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 650.989
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.790387
Right Arm Q3 power supply current : 892.924
Right Arm Q3 momentum : 2.24404
Right Arm Q3 gauss meter : 0.4005
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1688.26
Left Arm Q1 momentum : 2.24404
Left Arm Q1 gauss meter : -0.14301
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 966.242
Left Arm Q2 momentum : 2.24394
Left Arm Q2 gauss meter : 0.5098
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 766.955
Left Arm D1 momentum : 2.24407
Left Arm D1 NMR : 0.830344
Left Arm Q3 power supply current : 893.277
Left Arm Q3 momentum : 2.24375
Left Arm Q3 gauss meter : -0.4456
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0220391
Current on Unser monitor : 1.32474
Current on Upstream bcm : 0.0241865
Current on Downstream bcm : 0.0198918
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 2391.63
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : -44988
haL1_Fan_frequency_R : 65.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.13
haSC200_6_Sensor_2_R : 223.72
haSC200_6_Sensor_3_R : -0.25
haSC200_6_Sensor_4_R : 35.54
haHe_Omega_DPG_Sensor_R : 5.752
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.86
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 94.5
haITC502_4_Sensor_3_R : 79.5
haITC502_5_Sensor_1_R : 5.83
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 208.1
haITC502_6_Sensor_1_R : 5.83
haITC502_6_Sensor_2_R : 5.86
haITC502_6_Sensor_3_R : 27.35
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4895
HacR_VPM_LVDT:VALr : 321
HacR_HPE1313A:0_Ch58 : -0.517578
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.834473
HacR_alignROLL : -0.354688
HacR_alignPITCH : -0.035342
HacR_alignHPT : 2.58274
HacL_HPM_LVDT:VALr : -6985
HacL_VPM_LVDT:VALr : -365
HacL_HPE1313A:0_Ch58 : -0.307617
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.338379
HacL_alignROLL : 0.0305358
HacL_alignPITCH : 0.0294597
HacL_alignHPT : 4.05483
Right Arm Angle Floor Angle : 53.5
Right Arm Angle Vernier : 17.9
Right Arm Scattering Angle : 53.7827
Left Arm Angle Floor Angle : 55.5
Left Arm Angle Vernier : 87
Left Arm Scattering Angle : 55.795
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field :
Laser attenuation Hall A : 80
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88