User name adev
Log entry time 23:33:55 on October 2, 2000
Entry number 49127
keyword=Start_Run_1340_Tar=carbon,Type=Optics,Pmom=2.244,Emom=2.244,Ene=2384,Angle_e=17.731,Angle_h=17.769
Beginning-of-run EPICS data for Run Number 1340 at Mon Oct 2 23:33:43 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=5,ps3=1,ps4=1,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1687.35
Right Arm Q1 momentum : 2.24401
Right Arm Q1 gauss meter : -0.04216
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 965.809
Right Arm Q2 momentum : 2.24415
Right Arm Q2 gauss meter : 0.5077
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 785.39
Right Arm D1 momentum : 2.24407
Right Arm D1 NMR : 0.832747
Right Arm Q3 power supply current : 893.066
Right Arm Q3 momentum : 2.2444
Right Arm Q3 gauss meter : 0.4005
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1688.26
Left Arm Q1 momentum : 2.24404
Left Arm Q1 gauss meter : -0.14298
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 966.119
Left Arm Q2 momentum : 2.24366
Left Arm Q2 gauss meter : 0.5098
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 766.93
Left Arm D1 momentum : 2.24407
Left Arm D1 NMR : 0.830341
Left Arm Q3 power supply current : 893.419
Left Arm Q3 momentum : 2.2441
Left Arm Q3 gauss meter : -0.4455
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.28937
Current on Unser monitor : 7.18297
Current on Upstream bcm : 5.35513
Current on Downstream bcm : 5.22361
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 5.33856
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 732013
haL1_Fan_frequency_R : 63.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.13
haSC200_6_Sensor_2_R : 224.16
haSC200_6_Sensor_3_R : -0.22
haSC200_6_Sensor_4_R : 35.52
haHe_Omega_DPG_Sensor_R : 5.665
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.87
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 106.1
haITC502_4_Sensor_3_R : 82.6
haITC502_5_Sensor_1_R : 5.84
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 212.1
haITC502_6_Sensor_1_R : 5.84
haITC502_6_Sensor_2_R : 5.92
haITC502_6_Sensor_3_R : 27.37
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1328
HacR_VPM_LVDT:VALr : -798
HacR_HPE1313A:0_Ch58 : -0.543945
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.800293
HacR_alignROLL : -0.320016
HacR_alignPITCH : -0.0108612
HacR_alignHPT : -1.31133
HacL_HPM_LVDT:VALr : -7304
HacL_VPM_LVDT:VALr : 1824
HacL_HPE1313A:0_Ch58 : -0.163086
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.0976562
HacL_alignROLL : 0.249489
HacL_alignPITCH : -0.0991957
HacL_alignHPT : 4.31175
Right Arm Angle Floor Angle : 17.5
Right Arm Angle Vernier : 10.9
Right Arm Scattering Angle : 17.7687
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 76.2
Left Arm Scattering Angle : 17.731
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 55
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88