Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 07:29:43 on October 3, 2000
Entry number 49162
keyword=Start_Run_1350_Tar=4He-10cm,Type=Elastic,Pmom=2.31347,Emom=1.657,Ene=2384,Angle_e=17.731,Angle_h=19.853
Beginning-of-run EPICS data for Run Number 1350 at Tue Oct 3 07:29:31 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=260,ps3=18,ps4=10,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1246
Right Arm Q1 momentum : 1.65706
Right Arm Q1 gauss meter : 0.03142
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 713.364
Right Arm Q2 momentum : 1.65757
Right Arm Q2 gauss meter : -0.3757
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 571.016
Right Arm D1 momentum : 1.6571
Right Arm D1 NMR : 0.61493
Right Arm Q3 power supply current : 659.106
Right Arm Q3 momentum : 1.65642
Right Arm Q3 gauss meter : -0.2959
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1740.55
Left Arm Q1 momentum : 2.31354
Left Arm Q1 gauss meter : -0.14741
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 996.267
Left Arm Q2 momentum : 2.31367
Left Arm Q2 gauss meter : 0.5256
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 792.562
Left Arm D1 momentum : 2.31347
Left Arm D1 NMR : 0.856092
Left Arm Q3 power supply current : 920.941
Left Arm Q3 momentum : 2.31323
Left Arm Q3 gauss meter : -0.4594
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.5358
Current on Unser monitor : 41.3546
Current on Upstream bcm : 40.0647
Current on Downstream bcm : 39.0069
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 40.1351
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 63.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.86
haSC200_6_Sensor_2_R : 225.84
haSC200_6_Sensor_3_R : -0.45
haSC200_6_Sensor_4_R : 35.39
haHe_Omega_DPG_Sensor_R : 5.658
haITC502_1_Sensor_1_R : 5.79
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.96
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 108.6
haITC502_4_Sensor_3_R : 82.2
haITC502_5_Sensor_1_R : 5.87
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 204.6
haITC502_6_Sensor_1_R : 5.93
haITC502_6_Sensor_2_R : 6.03
haITC502_6_Sensor_3_R : 27.08
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -3627
HacR_VPM_LVDT:VALr : -475
HacR_HPE1313A:0_Ch58 : -0.529785
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.779785
HacR_alignROLL : -0.299494
HacR_alignPITCH : -0.0241239
HacR_alignHPT : 1.2493
HacL_HPM_LVDT:VALr : -7335
HacL_VPM_LVDT:VALr : 1824
HacL_HPE1313A:0_Ch58 : -0.164062
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0942383
HacL_alignROLL : 0.251841
HacL_alignPITCH : -0.0980275
HacL_alignHPT : 4.33856
Right Arm Angle Floor Angle : 19.5
Right Arm Angle Vernier : 28.5
Right Arm Scattering Angle : 19.8528
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 76.2
Left Arm Scattering Angle : 17.7308
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 195
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88