User name adev
Log entry time 08:09:18 on October 3, 2000
Entry number 49166
keyword=Start_Run_1351_Tar=4He-10cm,Type=Elastic,Pmom=2.31347,Emom=1.657,Ene=2384,Angle_e=17.731,Angle_h=19.853
Beginning-of-run EPICS data for Run Number 1351 at Tue Oct 3 08:09:05 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=260,ps3=18,ps4=10,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1246.1
Right Arm Q1 momentum : 1.6572
Right Arm Q1 gauss meter : 0.03141
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 713.194
Right Arm Q2 momentum : 1.65718
Right Arm Q2 gauss meter : -0.3758
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 571.021
Right Arm D1 momentum : 1.6571
Right Arm D1 NMR : 0.614931
Right Arm Q3 power supply current : 659.185
Right Arm Q3 momentum : 1.65662
Right Arm Q3 gauss meter : -0.2959
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1740.58
Left Arm Q1 momentum : 2.31359
Left Arm Q1 gauss meter : -0.14744
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 996.363
Left Arm Q2 momentum : 2.3139
Left Arm Q2 gauss meter : 0.5257
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 792.56
Left Arm D1 momentum : 2.31347
Left Arm D1 NMR : 0.856092
Left Arm Q3 power supply current : 921.028
Left Arm Q3 momentum : 2.31345
Left Arm Q3 gauss meter : -0.4594
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.6584
Current on Unser monitor : 40.439
Current on Upstream bcm : 40.1066
Current on Downstream bcm : 39.119
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 40.0843
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 63.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.81
haSC200_6_Sensor_2_R : 225.77
haSC200_6_Sensor_3_R : -0.48
haSC200_6_Sensor_4_R : 35.39
haHe_Omega_DPG_Sensor_R : 5.604
haITC502_1_Sensor_1_R : 5.79
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.95
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 108.6
haITC502_4_Sensor_3_R : 82.2
haITC502_5_Sensor_1_R : 5.86
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 204.5
haITC502_6_Sensor_1_R : 5.95
haITC502_6_Sensor_2_R : 6.06
haITC502_6_Sensor_3_R : 27.07
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -3625
HacR_VPM_LVDT:VALr : -468
HacR_HPE1313A:0_Ch58 : -0.529297
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.780762
HacR_alignROLL : -0.300598
HacR_alignPITCH : -0.0244393
HacR_alignHPT : 1.24769
HacL_HPM_LVDT:VALr : -7333
HacL_VPM_LVDT:VALr : 1833
HacL_HPE1313A:0_Ch58 : -0.164551
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.0942383
HacL_alignROLL : 0.251916
HacL_alignPITCH : -0.0976646
HacL_alignHPT : 4.34075
Right Arm Angle Floor Angle : 19.5
Right Arm Angle Vernier : 28.5
Right Arm Scattering Angle : 19.8528
Left Arm Angle Floor Angle : 17.5
Left Arm Angle Vernier : 76.2
Left Arm Scattering Angle : 17.7308
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 195
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88