• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 12:11:10 on October 3, 2000

    Entry number 49181

    keyword=Start_Run_1356_Tar=4He-10cm,Type=Pulser,Pmom=2.105,Emom=0.7438,Ene=2384,Angle_e=58.831,Angle_h=16.88
    Beginning-of-run EPICS data for Run Number 1356 at Tue Oct  3 12:10:57 EDT 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=10000,ps2=10000,ps3=10000,ps4=10000,ps5=1,ps6=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 559.195
    Right Arm Q1 momentum                    : 0.743675
    Right Arm Q1 gauss meter                 : 0.014264
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 320.187
    Right Arm Q2 momentum                    : 0.743985
    Right Arm Q2 gauss meter                 : -0.16942
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 253.927
    Right Arm D1 momentum                    : 0.7438
    Right Arm D1 NMR                         : 0.276015
    Right Arm Q3 power supply current        : 296.252
    Right Arm Q3 momentum                    : 0.744521
    Right Arm Q3 gauss meter                 : -0.13321
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1583.54
    Left Arm Q1 momentum                      : 2.10484
    Left Arm Q1 gauss meter                   : -0.13419
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 906.559
    Left Arm Q2 momentum                      : 2.10534
    Left Arm Q2 gauss meter                   : 0.4784
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 700.009
    Left Arm D1 momentum                      : 2.06248
    Left Arm D1 NMR                           : 0.763175
    Left Arm Q3 power supply current          : 838.036
    Left Arm Q3 momentum                      : 2.10499
    Left Arm Q3 gauss meter                   : -0.4179
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 0.022962
    Current on Unser monitor                : 1.46403
    Current on Upstream bcm                 : 0.0244325
    Current on Downstream bcm               : 0.0214914
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
     Current on IBC0L02 (source)            : 0.00142881
    Beam energy                             : 2391.63
    MBSY1c magnet current (amp)             : 99.5348
     Radiator 5V Linear Supply              : 
     Radiator Encoder                       : 
    haBDSPOS                                 : 6.517e+06
    haL1_Fan_frequency_R                     : 65.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 243.06
    haSC200_6_Sensor_2_R                     : 223.91
    haSC200_6_Sensor_3_R                     : -0.37
    haSC200_6_Sensor_4_R                     : 35.42
    haHe_Omega_DPG_Sensor_R                  : 5.766
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.79
    haITC502_1_Sensor_3_R                    : 5.86
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 108.7
    haITC502_4_Sensor_3_R                    : 82
    haITC502_5_Sensor_1_R                    : 5.84
    haITC502_5_Sensor_2_R                    : 5.8
    haITC502_5_Sensor_3_R                    : 203.7
    haITC502_6_Sensor_1_R                    : 5.84
    haITC502_6_Sensor_2_R                    : 6.04
    haITC502_6_Sensor_3_R                    : 27.04
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4775
     HacR_VPM_LVDT:VALr                     : 245
     HacR_HPE1313A:0_Ch58                   : -0.53125
     HacR_HPE1313A:0_Ch55                   : 21.875
     HacR_HPE1313A:0_Ch54                   : -0.787598
     HacR_alignROLL                         : -0.307872
     HacR_alignPITCH                        : -0.0236752
     HacR_alignHPT                          : 2.42174
     HacL_HPM_LVDT:VALr                     : -7595
     HacL_VPM_LVDT:VALr                     : 2299
     HacL_HPE1313A:0_Ch58                   : -0.158203
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.0996094
     HacL_alignROLL                         : 0.247573
     HacL_alignPITCH                        : -0.103414
     HacL_alignHPT                          : 4.63447
    Right Arm Angle Floor Angle               : 58.5
    Right Arm Angle Vernier                   : 23.1
    Right Arm Scattering Angle                : 58.8137
    Left Arm Angle Floor Angle                 : 17.5
    Left Arm Angle Vernier                     : 76.2
    Left Arm Scattering Angle                  : 17.7288
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 120
    Laser power  Hall A                      : 63
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88