Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 16:47:50 on October 3, 2000
Entry number 49203
keyword=Start_Run_1366_Tar=4He-10cm,Type=Pulser,Pmom=2.105,Emom=0.7438,Ene=2384,Angle_e=58.831,Angle_h=16.88
Beginning-of-run EPICS data for Run Number 1366 at Tue Oct 3 16:47:37 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10000,ps3=1,ps4=10000,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 0.0001539
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 320.193
Right Arm Q2 momentum : 0.744
Right Arm Q2 gauss meter : -0.1694
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 212.291
Right Arm D1 momentum : 0.7062
Right Arm D1 NMR : 0.262062
Right Arm Q3 power supply current : -0.0393796
Right Arm Q3 momentum : -9.89665e-05
Right Arm Q3 gauss meter : -0.0006482
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1253.49
Left Arm Q1 momentum : 1.66614
Left Arm Q1 gauss meter : -0.10563
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 906.456
Left Arm Q2 momentum : 2.1051
Left Arm Q2 gauss meter : 0.4775
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 716.019
Left Arm D1 momentum : 2.105
Left Arm D1 NMR : 0.778899
Left Arm Q3 power supply current : 1.94339
Left Arm Q3 momentum : 0.00488142
Left Arm Q3 gauss meter : -9.78e-05
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0237032
Current on Unser monitor : 1.19835
Current on Upstream bcm : 0.0253302
Current on Downstream bcm : 0.0220763
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 2391.63
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.52
haSC200_6_Sensor_2_R : 15
haSC200_6_Sensor_3_R : -0.25
haSC200_6_Sensor_4_R : 35.52
haHe_Omega_DPG_Sensor_R : 0.059
haITC502_1_Sensor_1_R : 42.9
haITC502_1_Sensor_2_R : 43.06
haITC502_1_Sensor_3_R : 43.63
haITC502_4_Sensor_1_R : 48.4
haITC502_4_Sensor_2_R : 111.5
haITC502_4_Sensor_3_R : 85.6
haITC502_5_Sensor_1_R : 43.69
haITC502_5_Sensor_2_R : 43.22
haITC502_5_Sensor_3_R : 130.1
haITC502_6_Sensor_1_R : 43.58
haITC502_6_Sensor_2_R : 43.21
haITC502_6_Sensor_3_R : 19.04
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4773
HacR_VPM_LVDT:VALr : 264
HacR_HPE1313A:0_Ch58 : -0.522949
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.787109
HacR_alignROLL : -0.30671
HacR_alignPITCH : -0.0306064
HacR_alignHPT : 2.41997
HacL_HPM_LVDT:VALr : -7936
HacL_VPM_LVDT:VALr : 2410
HacL_HPE1313A:0_Ch58 : -0.147949
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.00488281
HacL_alignROLL : 0.33713
HacL_alignPITCH : -0.133284
HacL_alignHPT : 4.97473
Right Arm Angle Floor Angle : 58.5
Right Arm Angle Vernier : 23.1
Right Arm Scattering Angle : 58.8137
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10.2
Left Arm Scattering Angle : 16.8461
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 80
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88