User name adev
Log entry time 01:02:57 on October 4, 2000
Entry number 49216
keyword=Start_Run_1368_Tar=carbon,Type=QuasiElastic,Pmom=2.105,Emom=0.7438,Ene=2384,Angle_e=58.814,Angle_h=16.848
Beginning-of-run EPICS data for Run Number 1368 at Wed Oct 4 01:02:44 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=50,ps2=200,ps3=210,ps4=10,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 559.37
Right Arm Q1 momentum : 0.743908
Right Arm Q1 gauss meter : 0.014228
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 320.079
Right Arm Q2 momentum : 0.743734
Right Arm Q2 gauss meter : -0.1694
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 255.436
Right Arm D1 momentum : 0.7438
Right Arm D1 NMR : 0.276015
Right Arm Q3 power supply current : 295.988
Right Arm Q3 momentum : 0.743859
Right Arm Q3 gauss meter : -0.13308
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1583.54
Left Arm Q1 momentum : 2.10484
Left Arm Q1 gauss meter : -0.13407
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 906.391
Left Arm Q2 momentum : 2.10513
Left Arm Q2 gauss meter : 0.4783
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 716.569
Left Arm D1 momentum : 2.105
Left Arm D1 NMR : 0.778898
Left Arm Q3 power supply current : 838.167
Left Arm Q3 momentum : 2.10532
Left Arm Q3 gauss meter : -0.4179
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 40.0883
Current on Unser monitor : 41.5534
Current on Upstream bcm : 40.5758
Current on Downstream bcm : 39.5397
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 40.5484
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 732011
haL1_Fan_frequency_R : 25
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.06
haSC200_6_Sensor_2_R : 71.74
haSC200_6_Sensor_3_R : -0.35
haSC200_6_Sensor_4_R : 35.49
haHe_Omega_DPG_Sensor_R : 8.877
haITC502_1_Sensor_1_R : 6.21
haITC502_1_Sensor_2_R : 6.19
haITC502_1_Sensor_3_R : 6.36
haITC502_4_Sensor_1_R : 6.6
haITC502_4_Sensor_2_R : 160.9
haITC502_4_Sensor_3_R : 157.9
haITC502_5_Sensor_1_R : 6.27
haITC502_5_Sensor_2_R : 6.21
haITC502_5_Sensor_3_R : 232.3
haITC502_6_Sensor_1_R : 6.29
haITC502_6_Sensor_2_R : 6.28
haITC502_6_Sensor_3_R : 27.92
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4758
HacR_VPM_LVDT:VALr : 260
HacR_HPE1313A:0_Ch58 : -0.525391
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.791016
HacR_alignROLL : -0.31077
HacR_alignPITCH : -0.0282292
HacR_alignHPT : 2.40563
HacL_HPM_LVDT:VALr : -7916
HacL_VPM_LVDT:VALr : 2454
HacL_HPE1313A:0_Ch58 : -0.15332
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.00634766
HacL_alignROLL : 0.335659
HacL_alignPITCH : -0.128407
HacL_alignHPT : 4.95198
Right Arm Angle Floor Angle : 58.5
Right Arm Angle Vernier : 23.1
Right Arm Scattering Angle : 58.8138
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10.5
Left Arm Scattering Angle : 16.848
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 195
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88