    User name adev

    Log entry time 02:55:53 on October 4, 2000

    Entry number 49225

    keyword=Start_Run_1370_Tar=carbon,Type=QuasiElastic,Pmom=2.105,Emom=0.7438,Ene=2384,Angle_e=58.814,Angle_h=16.848
    Beginning-of-run EPICS data for Run Number 1370 at Wed Oct  4 02:55:38 EDT 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=50,ps2=200,ps3=210,ps4=10,ps5=1,ps6=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 559.3
    Right Arm Q1 momentum                    : 0.743814
    Right Arm Q1 gauss meter                 : 0.014223
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 320.241
    Right Arm Q2 momentum                    : 0.744112
    Right Arm Q2 gauss meter                 : -0.16943
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 255.427
    Right Arm D1 momentum                    : 0.743798
    Right Arm D1 NMR                         : 0.276015
    Right Arm Q3 power supply current        : 295.771
    Right Arm Q3 momentum                    : 0.743314
    Right Arm Q3 gauss meter                 : -0.13307
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1583.57
    Left Arm Q1 momentum                      : 2.10489
    Left Arm Q1 gauss meter                   : -0.13407
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 906.18
    Left Arm Q2 momentum                      : 2.10446
    Left Arm Q2 gauss meter                   : 0.4782
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 716.57
    Left Arm D1 momentum                      : 2.105
    Left Arm D1 NMR                           : 0.778898
    Left Arm Q3 power supply current          : 838.068
    Left Arm Q3 momentum                      : 2.10507
    Left Arm Q3 gauss meter                   : -0.4179
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 39.6137
    Current on Unser monitor                : 40.9415
    Current on Upstream bcm                 : 40.1273
    Current on Downstream bcm               : 39.0365
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
     Current on IBC0L02 (source)            : 40.0474
    Beam energy                             : 2391.63
    MBSY1c magnet current (amp)             : 99.5348
     Radiator 5V Linear Supply              : 
     Radiator Encoder                       : 
    haBDSPOS                                 : 732011
    haL1_Fan_frequency_R                     : 24.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 243.03
    haSC200_6_Sensor_2_R                     : 83.14
    haSC200_6_Sensor_3_R                     : -0.33
    haSC200_6_Sensor_4_R                     : 35.49
    haHe_Omega_DPG_Sensor_R                  : 3.009
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.79
    haITC502_1_Sensor_3_R                    : 5.94
    haITC502_4_Sensor_1_R                    : 6.1
    haITC502_4_Sensor_2_R                    : 155.2
    haITC502_4_Sensor_3_R                    : 112.8
    haITC502_5_Sensor_1_R                    : 5.86
    haITC502_5_Sensor_2_R                    : 5.8
    haITC502_5_Sensor_3_R                    : 229.6
    haITC502_6_Sensor_1_R                    : 5.87
    haITC502_6_Sensor_2_R                    : 5.86
    haITC502_6_Sensor_3_R                    : 27.84
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4766
     HacR_VPM_LVDT:VALr                     : 268
     HacR_HPE1313A:0_Ch58                   : -0.525391
     HacR_HPE1313A:0_Ch55                   : 21.875
     HacR_HPE1313A:0_Ch54                   : -0.792969
     HacR_alignROLL                         : -0.312307
     HacR_alignPITCH                        : -0.0281624
     HacR_alignHPT                          : 2.41539
     HacL_HPM_LVDT:VALr                     : -7914
     HacL_VPM_LVDT:VALr                     : 2466
     HacL_HPE1313A:0_Ch58                   : -0.15332
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.00634766
     HacL_alignROLL                         : 0.335506
     HacL_alignPITCH                        : -0.128258
     HacL_alignHPT                          : 4.9487
    Right Arm Angle Floor Angle               : 58.5
    Right Arm Angle Vernier                   : 23.1
    Right Arm Scattering Angle                : 58.8138
    Left Arm Angle Floor Angle                 : 17
    Left Arm Angle Vernier                     : 10.5
    Left Arm Scattering Angle                  : 16.848
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 195
    Laser power  Hall A                      : 63
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88