• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 05:09:49 on October 4, 2000

    Entry number 49237

    keyword=Start_Run_1373_Tar=4He-10cm,Type=QuasiElastic,Pmom=1.765,Emom=1.1935,Ene=2384,Angle_e=36.409,Angle_h=16.848
    Beginning-of-run EPICS data for Run Number 1373 at Wed Oct  4 05:09:38 EDT 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=200,ps2=200,ps3=1000,ps4=32,ps5=1,ps6=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 897.47
    Right Arm Q1 momentum                    : 1.19355
    Right Arm Q1 gauss meter                 : 0.02272
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 513.529
    Right Arm Q2 momentum                    : 1.19323
    Right Arm Q2 gauss meter                 : -0.2708
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 409.788
    Right Arm D1 momentum                    : 1.19348
    Right Arm D1 NMR                         : 0.442886
    Right Arm Q3 power supply current        : 474.906
    Right Arm Q3 momentum                    : 1.1935
    Right Arm Q3 gauss meter                 : -0.2132
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1327.76
    Left Arm Q1 momentum                      : 1.76486
    Left Arm Q1 gauss meter                   : -0.1125
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 759.882
    Left Arm Q2 momentum                      : 1.76471
    Left Arm Q2 gauss meter                   : 0.4012
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 594.289
    Left Arm D1 momentum                      : 1.76499
    Left Arm D1 NMR                           : 0.65316
    Left Arm Q3 power supply current          : 702.788
    Left Arm Q3 momentum                      : 1.76527
    Left Arm Q3 gauss meter                   : -0.3503
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 19.1877
    Current on Unser monitor                : 20.8727
    Current on Upstream bcm                 : 19.4495
    Current on Downstream bcm               : 18.9259
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
     Current on IBC0L02 (source)            : 19.3943
    Beam energy                             : 2391.63
    MBSY1c magnet current (amp)             : 99.5348
     Radiator 5V Linear Supply              : 
     Radiator Encoder                       : 
    haBDSPOS                                 : 6.517e+06
    haL1_Fan_frequency_R                     : 53
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 243.05
    haSC200_6_Sensor_2_R                     : 83.67
    haSC200_6_Sensor_3_R                     : -0.33
    haSC200_6_Sensor_4_R                     : 35.47
    haHe_Omega_DPG_Sensor_R                  : 5.327
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.79
    haITC502_1_Sensor_3_R                    : 5.9
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 147.6
    haITC502_4_Sensor_3_R                    : 79.4
    haITC502_5_Sensor_1_R                    : 5.85
    haITC502_5_Sensor_2_R                    : 5.8
    haITC502_5_Sensor_3_R                    : 213.8
    haITC502_6_Sensor_1_R                    : 5.87
    haITC502_6_Sensor_2_R                    : 5.94
    haITC502_6_Sensor_3_R                    : 27.08
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -1649
     HacR_VPM_LVDT:VALr                     : -5
     HacR_HPE1313A:0_Ch58                   : -0.548828
     HacR_HPE1313A:0_Ch55                   : 21.9238
     HacR_HPE1313A:0_Ch54                   : -0.911621
     HacR_alignROLL                         : -0.43255
     HacR_alignPITCH                        : -0.00662377
     HacR_alignHPT                          : -0.939783
     HacL_HPM_LVDT:VALr                     : -7874
     HacL_VPM_LVDT:VALr                     : 2266
     HacL_HPE1313A:0_Ch58                   : -0.157227
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.0170898
     HacL_alignROLL                         : 0.325129
     HacL_alignPITCH                        : -0.125053
     HacL_alignHPT                          : 4.9101
    Right Arm Angle Floor Angle               : 36.5
    Right Arm Angle Vernier                   : -51
    Right Arm Scattering Angle                : 36.4094
    Left Arm Angle Floor Angle                 : 17
    Left Arm Angle Vernier                     : 10.5
    Left Arm Scattering Angle                  : 16.8483
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 134
    Laser power  Hall A                      : 63
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88