    Log entry time 08:26:06 on October 4,2000

    Entry number 49248

    keyword=Shift summary

    recover from Q3 on SR which tripped off (interlock fault?)
    40 uA unrastered on 12C target since 4He target is still being cooled.
    .
    run 1368 - 12C run, pm about 30 MeV/c ... coincs count at about 40 Hz.

    -# Data taking history
    ***************
    ... Run 1368 ..... Carbon (e,e'p) ..... 1:01 / 1:58 ..... Raster off / Good run
    ... Run 1369 ..... Carbon (e,e'p) ..... 1:58 / 2:53 ..... Raster off / Good run
    ... Run 1370 ..... Raster checks end with a SPOT++ size 4x4
    ... Run 1371 ..... Carbon (e,e'p) ..... 3:01 / 3:48 ..... Raster on / Good run
    ... Run 1372 ..... 4He(e,e'p) ........... 4:09 / 4:24 ..... Raster on / Good run / PY-1A
    ... Run 1373 ..... 4He(e,e'p) ........... 5:08 / 5:18 ..... Ratser on / Good run / PY-1D
    .
    run 1373 unfortunately did not have the correct coinc trigger downloaded.
    .
    at 5:20 meekins goes into hall to work on 4He target.
    .
    at 6:55 michaels goes into hall to work on spectrometer trigger.
    .