User name adev
Log entry time 12:11:00 on October 4, 2000
Entry number 49273
keyword=Start_Run_1385_Tar=4He-10cm,Type=pion_prod,Thcm=py_1d,Pmom=1.765,Emom=1.1935,Ene=2384,Angle_e=36.409,Angle_h=16.848
Beginning-of-run EPICS data for Run Number 1385 at Wed Oct 4 12:10:48 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3150,ps2=2430,ps3=14325,ps4=440,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 897.365
Right Arm Q1 momentum : 1.19341
Right Arm Q1 gauss meter : 0.02272
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 513.622
Right Arm Q2 momentum : 1.19345
Right Arm Q2 gauss meter : -0.2709
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 409.996
Right Arm D1 momentum : 1.1935
Right Arm D1 NMR : 0.442894
Right Arm Q3 power supply current : 475.019
Right Arm Q3 momentum : 1.19379
Right Arm Q3 gauss meter : -0.2133
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1327.94
Left Arm Q1 momentum : 1.76509
Left Arm Q1 gauss meter : -0.1125
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 760.214
Left Arm Q2 momentum : 1.76548
Left Arm Q2 gauss meter : 0.4013
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 594.287
Left Arm D1 momentum : 1.76499
Left Arm D1 NMR : 0.653159
Left Arm Q3 power supply current : 702.778
Left Arm Q3 momentum : 1.76525
Left Arm Q3 gauss meter : -0.3504
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 58.8086
Current on Unser monitor : 61.0969
Current on Upstream bcm : 59.3572
Current on Downstream bcm : 58.26
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 59.5839
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 65
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.35
haSC200_6_Sensor_2_R : 227.32
haSC200_6_Sensor_3_R : -0.1
haSC200_6_Sensor_4_R : 35.65
haHe_Omega_DPG_Sensor_R : 5.593
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 6
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 144.7
haITC502_4_Sensor_3_R : 74.1
haITC502_5_Sensor_1_R : 5.89
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 205.8
haITC502_6_Sensor_1_R : 5.98
haITC502_6_Sensor_2_R : 5.95
haITC502_6_Sensor_3_R : 27.02
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1653
HacR_VPM_LVDT:VALr : 23
HacR_HPE1313A:0_Ch58 : -0.541016
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.895996
HacR_alignROLL : -0.417273
HacR_alignPITCH : -0.0133546
HacR_alignHPT : -0.942894
HacL_HPM_LVDT:VALr : -7874
HacL_VPM_LVDT:VALr : 2211
HacL_HPE1313A:0_Ch58 : -0.156738
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0200195
HacL_alignROLL : 0.322493
HacL_alignPITCH : -0.125638
HacL_alignHPT : 4.90913
Right Arm Angle Floor Angle : 36.5
Right Arm Angle Vernier : -51
Right Arm Scattering Angle : 36.4094
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10.5
Left Arm Scattering Angle : 16.8483
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 257
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88