User name adev
Log entry time 15:43:36 on October 4, 2000
Entry number 49290
keyword=Start_Run_1391_Tar=4He-10cm,Type=Elastic,Pmom=2.35974,Emom=1.1935,Ene=2384,Angle_e=36.409,Angle_h=17.733
Beginning-of-run EPICS data for Run Number 1391 at Wed Oct 4 15:43:20 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3120,ps2=2410,ps3=428,ps4=84,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 897.435
Right Arm Q1 momentum : 1.1935
Right Arm Q1 gauss meter : 0.02273
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 513.611
Right Arm Q2 momentum : 1.19342
Right Arm Q2 gauss meter : -0.2708
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 409.996
Right Arm D1 momentum : 1.1935
Right Arm D1 NMR : 0.442893
Right Arm Q3 power supply current : 474.843
Right Arm Q3 momentum : 1.19335
Right Arm Q3 gauss meter : -0.2133
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1775.27
Left Arm Q1 momentum : 2.35969
Left Arm Q1 gauss meter : -0.15032
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1015.91
Left Arm Q2 momentum : 2.35929
Left Arm Q2 gauss meter : 0.5362
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 809.678
Left Arm D1 momentum : 2.35975
Left Arm D1 NMR : 0.873265
Left Arm Q3 power supply current : 939.502
Left Arm Q3 momentum : 2.35985
Left Arm Q3 gauss meter : -0.4687
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 59.1511
Current on Unser monitor : 61.1651
Current on Upstream bcm : 59.7686
Current on Downstream bcm : 58.5335
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 59.9762
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 63.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.53
haSC200_6_Sensor_2_R : 222.26
haSC200_6_Sensor_3_R : -0.03
haSC200_6_Sensor_4_R : 35.74
haHe_Omega_DPG_Sensor_R : 6.037
haITC502_1_Sensor_1_R : 5.74
haITC502_1_Sensor_2_R : 5.73
haITC502_1_Sensor_3_R : 5.96
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 121.5
haITC502_4_Sensor_3_R : 75.7
haITC502_5_Sensor_1_R : 5.84
haITC502_5_Sensor_2_R : 5.75
haITC502_5_Sensor_3_R : 209.5
haITC502_6_Sensor_1_R : 5.93
haITC502_6_Sensor_2_R : 5.91
haITC502_6_Sensor_3_R : 27.06
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1654
HacR_VPM_LVDT:VALr : 15
HacR_HPE1313A:0_Ch58 : -0.541016
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.89502
HacR_alignROLL : -0.415682
HacR_alignPITCH : -0.013936
HacR_alignHPT : -0.943801
HacL_HPM_LVDT:VALr : -7370
HacL_VPM_LVDT:VALr : 2075
HacL_HPE1313A:0_Ch58 : -0.163086
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0800781
HacL_alignROLL : 0.265329
HacL_alignPITCH : -0.119525
HacL_alignHPT : 4.37454
Right Arm Angle Floor Angle : 36.5
Right Arm Angle Vernier : -51
Right Arm Scattering Angle : 36.4094
Left Arm Angle Floor Angle : 18
Left Arm Angle Vernier : -10.2
Left Arm Scattering Angle : 17.7326
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 260
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88