Log entry time 17:28:23 on October 4, 2000
Entry number 49311
keyword=Start_Run_1399_Tar=4He-10cm,Type=Elastic,Pmom=2.35974,Emom=1.01480,Ene=2384,Angle_e=44.966,Angle_h=17.733
Beginning-of-run EPICS data for Run Number 1399 at Wed Oct 4 17:28:09 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=9120,ps2=6410,ps3=1,ps4=244,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 763
Right Arm Q1 momentum : 1.01472
Right Arm Q1 gauss meter : 0.019377
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 436.746
Right Arm Q2 momentum : 1.01482
Right Arm Q2 gauss meter : -0.2305
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 348.005
Right Arm D1 momentum : 1.01482
Right Arm D1 NMR : 0.376587
Right Arm Q3 power supply current : 403.869
Right Arm Q3 momentum : 1.01498
Right Arm Q3 gauss meter : -0.18143
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1775.31
Left Arm Q1 momentum : 2.35974
Left Arm Q1 gauss meter : -0.15032
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1016.12
Left Arm Q2 momentum : 2.35977
Left Arm Q2 gauss meter : 0.536
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 809.668
Left Arm D1 momentum : 2.35974
Left Arm D1 NMR : 0.873265
Left Arm Q3 power supply current : 939.355
Left Arm Q3 momentum : 2.35948
Left Arm Q3 gauss meter : -0.4686
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 20.2338
Current on Unser monitor : 21.4857
Current on Upstream bcm : 20.4763
Current on Downstream bcm : 19.9914
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 20.4915
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 64.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.62
haSC200_6_Sensor_2_R : 178.95
haSC200_6_Sensor_3_R : 0
haSC200_6_Sensor_4_R : 35.79
haHe_Omega_DPG_Sensor_R : 5.669
haITC502_1_Sensor_1_R : 5.03
haITC502_1_Sensor_2_R : 5.02
haITC502_1_Sensor_3_R : 5.15
haITC502_4_Sensor_1_R : 5.2
haITC502_4_Sensor_2_R : 115.2
haITC502_4_Sensor_3_R : 75.3
haITC502_5_Sensor_1_R : 5.1
haITC502_5_Sensor_2_R : 5.04
haITC502_5_Sensor_3_R : 204.5
haITC502_6_Sensor_1_R : 5.17
haITC502_6_Sensor_2_R : 5.13
haITC502_6_Sensor_3_R : 26.99
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4893
HacR_VPM_LVDT:VALr : -69
HacR_HPE1313A:0_Ch58 : -0.544922
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.88623
HacR_alignROLL : -0.406699
HacR_alignPITCH : -0.0104787
HacR_alignHPT : 2.64827
HacL_HPM_LVDT:VALr : -7407
HacL_VPM_LVDT:VALr : 2134
HacL_HPE1313A:0_Ch58 : -0.162598
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.074707
HacL_alignROLL : 0.270516
HacL_alignPITCH : -0.120909
HacL_alignHPT : 4.41451
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -37
Right Arm Scattering Angle : 44.9658
Left Arm Angle Floor Angle : 18
Left Arm Angle Vernier : -10.2
Left Arm Scattering Angle : 17.7323
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 138
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88