User name adev
Log entry time 18:11:16 on October 4, 2000
Entry number 49319
keyword=Start_Run_1403_Tar=4He-10cm,Type=Elastic,Pmom=2.35974,Emom=1.01480,Ene=2384,Angle_e=44.966,Angle_h=17.733
Beginning-of-run EPICS data for Run Number 1403 at Wed Oct 4 18:11:00 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=9120,ps2=6410,ps3=1,ps4=244,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 763.035
Right Arm Q1 momentum : 1.01476
Right Arm Q1 gauss meter : 0.019376
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 436.768
Right Arm Q2 momentum : 1.01487
Right Arm Q2 gauss meter : -0.2304
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 347.346
Right Arm D1 momentum : 1.0148
Right Arm D1 NMR : 0.37658
Right Arm Q3 power supply current : 403.75
Right Arm Q3 momentum : 1.01468
Right Arm Q3 gauss meter : -0.18138
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1775.31
Left Arm Q1 momentum : 2.35974
Left Arm Q1 gauss meter : -0.15031
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1016.18
Left Arm Q2 momentum : 2.35993
Left Arm Q2 gauss meter : 0.5362
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 809.669
Left Arm D1 momentum : 2.35974
Left Arm D1 NMR : 0.873264
Left Arm Q3 power supply current : 939.325
Left Arm Q3 momentum : 2.35941
Left Arm Q3 gauss meter : -0.4687
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 20.2494
Current on Unser monitor : 21.3401
Current on Upstream bcm : 20.4678
Current on Downstream bcm : 20.0311
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 20.4609
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 66
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.65
haSC200_6_Sensor_2_R : 179.15
haSC200_6_Sensor_3_R : 0.02
haSC200_6_Sensor_4_R : 35.77
haHe_Omega_DPG_Sensor_R : 5.658
haITC502_1_Sensor_1_R : 5.04
haITC502_1_Sensor_2_R : 5.02
haITC502_1_Sensor_3_R : 5.16
haITC502_4_Sensor_1_R : 5.2
haITC502_4_Sensor_2_R : 113.1
haITC502_4_Sensor_3_R : 74.8
haITC502_5_Sensor_1_R : 5.1
haITC502_5_Sensor_2_R : 5.04
haITC502_5_Sensor_3_R : 203.8
haITC502_6_Sensor_1_R : 5.17
haITC502_6_Sensor_2_R : 5.12
haITC502_6_Sensor_3_R : 26.98
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4901
HacR_VPM_LVDT:VALr : -70
HacR_HPE1313A:0_Ch58 : -0.543945
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.891113
HacR_alignROLL : -0.41174
HacR_alignPITCH : -0.0112436
HacR_alignHPT : 2.66002
HacL_HPM_LVDT:VALr : -7410
HacL_VPM_LVDT:VALr : 2132
HacL_HPE1313A:0_Ch58 : -0.162598
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.0742188
HacL_alignROLL : 0.271056
HacL_alignPITCH : -0.12011
HacL_alignHPT : 4.4176
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -37
Right Arm Scattering Angle : 44.9657
Left Arm Angle Floor Angle : 18
Left Arm Angle Vernier : -10.2
Left Arm Scattering Angle : 17.7323
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 138
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88