• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 22:33:07 on October 4, 2000

    Entry number 49333

    keyword=Start_Run_1407_Tar=4He-10cm,Type=QuasiElastic,Pmom=1.911,Emom=1.01480,Ene=2384,Angle_e=44.966,Angle_h=16.842
    Beginning-of-run EPICS data for Run Number 1407 at Wed Oct  4 22:32:49 EDT 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=200,ps2=320,ps3=1000,ps4=50,ps5=1,ps6=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 762.93
    Right Arm Q1 momentum                    : 1.01462
    Right Arm Q1 gauss meter                 : 0.019374
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 436.843
    Right Arm Q2 momentum                    : 1.01505
    Right Arm Q2 gauss meter                 : -0.2305
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 347.338
    Right Arm D1 momentum                    : 1.0148
    Right Arm D1 NMR                         : 0.376579
    Right Arm Q3 power supply current        : 403.821
    Right Arm Q3 momentum                    : 1.01486
    Right Arm Q3 gauss meter                 : -0.18138
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1437.66
    Left Arm Q1 momentum                      : 1.91094
    Left Arm Q1 gauss meter                   : -0.12181
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 822.828
    Left Arm Q2 momentum                      : 1.91089
    Left Arm Q2 gauss meter                   : 0.4343
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 646.039
    Left Arm D1 momentum                      : 1.91101
    Left Arm D1 NMR                           : 0.707159
    Left Arm Q3 power supply current          : 760.929
    Left Arm Q3 momentum                      : 1.91131
    Left Arm Q3 gauss meter                   : -0.3794
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 20.6649
    Current on Unser monitor                : 22.1058
    Current on Upstream bcm                 : 20.9165
    Current on Downstream bcm               : 20.4197
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
     Current on IBC0L02 (source)            : 20.8797
    Beam energy                             : 2391.63
    MBSY1c magnet current (amp)             : 99.5348
     Radiator 5V Linear Supply              : 
     Radiator Encoder                       : 
    haBDSPOS                                 : 6.517e+06
    haL1_Fan_frequency_R                     : 67.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 243.62
    haSC200_6_Sensor_2_R                     : 236.29
    haSC200_6_Sensor_3_R                     : 0.03
    haSC200_6_Sensor_4_R                     : 36
    haHe_Omega_DPG_Sensor_R                  : 5.771
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.79
    haITC502_1_Sensor_3_R                    : 5.92
    haITC502_4_Sensor_1_R                    : 6.1
    haITC502_4_Sensor_2_R                    : 107.4
    haITC502_4_Sensor_3_R                    : 75.2
    haITC502_5_Sensor_1_R                    : 5.87
    haITC502_5_Sensor_2_R                    : 5.8
    haITC502_5_Sensor_3_R                    : 204.3
    haITC502_6_Sensor_1_R                    : 5.89
    haITC502_6_Sensor_2_R                    : 5.86
    haITC502_6_Sensor_3_R                    : 26.92
    Right Arm Arm Collimator                 : 0.614893
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4912
     HacR_VPM_LVDT:VALr                     : -79
     HacR_HPE1313A:0_Ch58                   : -0.542969
     HacR_HPE1313A:0_Ch55                   : 22.0703
     HacR_HPE1313A:0_Ch54                   : -0.893555
     HacR_alignROLL                         : -0.414148
     HacR_alignPITCH                        : -0.0122074
     HacR_alignHPT                          : 2.67471
     HacL_HPM_LVDT:VALr                     : -8294
     HacL_VPM_LVDT:VALr                     : 2262
     HacL_HPE1313A:0_Ch58                   : -0.152832
     HacL_HPE1313A:0_Ch55                   : 23.6816
     HacL_HPE1313A:0_Ch54                   : -0.0161133
     HacL_alignROLL                         : 0.326981
     HacL_alignPITCH                        : -0.128119
     HacL_alignHPT                          : 5.37738
    Right Arm Angle Floor Angle               : 45
    Right Arm Angle Vernier                   : -37
    Right Arm Scattering Angle                : 44.9656
    Left Arm Angle Floor Angle                 : 17
    Left Arm Angle Vernier                     : 10
    Left Arm Scattering Angle                  : 16.8422
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 135
    Laser power  Hall A                      : 63
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88