User name adev
Log entry time 00:19:12 on October 5, 2000
Entry number 49345
keyword=Start_Run_1412_Tar=4He-10cm,Type=QuasiElastic,Pmom=1.911,Emom=1.01480,Ene=2384,Angle_e=44.966,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1412 at Thu Oct 5 00:18:56 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=600,ps2=1000,ps3=3000,ps4=150,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 763
Right Arm Q1 momentum : 1.01472
Right Arm Q1 gauss meter : 0.019373
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 436.612
Right Arm Q2 momentum : 1.01451
Right Arm Q2 gauss meter : -0.2305
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 347.347
Right Arm D1 momentum : 1.0148
Right Arm D1 NMR : 0.376581
Right Arm Q3 power supply current : 403.761
Right Arm Q3 momentum : 1.01471
Right Arm Q3 gauss meter : -0.18137
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1437.66
Left Arm Q1 momentum : 1.91094
Left Arm Q1 gauss meter : -0.12181
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 822.664
Left Arm Q2 momentum : 1.91051
Left Arm Q2 gauss meter : 0.4343
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 646.038
Left Arm D1 momentum : 1.91101
Left Arm D1 NMR : 0.707159
Left Arm Q3 power supply current : 760.894
Left Arm Q3 momentum : 1.91122
Left Arm Q3 gauss meter : -0.3794
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 59.2045
Current on Unser monitor : 60.9755
Current on Upstream bcm : 59.8313
Current on Downstream bcm : 58.5777
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 59.9251
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 65
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.55
haSC200_6_Sensor_2_R : 239.82
haSC200_6_Sensor_3_R : 0.02
haSC200_6_Sensor_4_R : 35.99
haHe_Omega_DPG_Sensor_R : 5.832
haITC502_1_Sensor_1_R : 5.81
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 106.5
haITC502_4_Sensor_3_R : 76.2
haITC502_5_Sensor_1_R : 5.91
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 201.8
haITC502_6_Sensor_1_R : 6
haITC502_6_Sensor_2_R : 5.96
haITC502_6_Sensor_3_R : 26.87
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4906
HacR_VPM_LVDT:VALr : -83
HacR_HPE1313A:0_Ch58 : -0.54248
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.894531
HacR_alignROLL : -0.415189
HacR_alignPITCH : -0.0125898
HacR_alignHPT : 2.66754
HacL_HPM_LVDT:VALr : -8294
HacL_VPM_LVDT:VALr : 2257
HacL_HPE1313A:0_Ch58 : -0.15332
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.0161133
HacL_alignROLL : 0.325899
HacL_alignPITCH : -0.127533
HacL_alignHPT : 5.3779
Right Arm Angle Floor Angle : 45
Right Arm Angle Vernier : -37
Right Arm Scattering Angle : 44.9657
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8422
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 250
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88