User name adev
Log entry time 16:15:44 on October 5, 2000
Entry number 49404
keyword=Start_Run_1435_Tar=4He-10cm,Type=Cosmic,Pmom=2.105,Emom=0.7438,Ene=2384,Angle_e=58.81,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1435 at Thu Oct 5 16:15:31 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=420,ps2=480,ps3=2070,ps4=92,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 559.16
Right Arm Q1 momentum : 0.743628
Right Arm Q1 gauss meter : 0.014274
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 320.224
Right Arm Q2 momentum : 0.744072
Right Arm Q2 gauss meter : -0.16944
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 254.055
Right Arm D1 momentum : 0.743801
Right Arm D1 NMR : 0.276015
Right Arm Q3 power supply current : 295.94
Right Arm Q3 momentum : 0.743738
Right Arm Q3 gauss meter : -0.13314
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1583.65
Left Arm Q1 momentum : 2.10498
Left Arm Q1 gauss meter : -0.13409
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 906.372
Left Arm Q2 momentum : 2.1049
Left Arm Q2 gauss meter : 0.4783
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 716.552
Left Arm D1 momentum : 2.10499
Left Arm D1 NMR : 0.778897
Left Arm Q3 power supply current : 838.216
Left Arm Q3 momentum : 2.10544
Left Arm Q3 gauss meter : -0.4179
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0310332
Current on Unser monitor : 0.212285
Current on Upstream bcm : 0.0350901
Current on Downstream bcm : 0.0269762
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 0.00142881
Beam energy : 2391.63
MBSY1c magnet current (amp) : 0.0377197
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 732017
haL1_Fan_frequency_R : 65.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.6
haSC200_6_Sensor_2_R : 219.78
haSC200_6_Sensor_3_R : 0.23
haSC200_6_Sensor_4_R : 36.1
haHe_Omega_DPG_Sensor_R : 5.669
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.87
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 111.5
haITC502_4_Sensor_3_R : 79.6
haITC502_5_Sensor_1_R : 5.87
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 206.8
haITC502_6_Sensor_1_R : 5.96
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 27.07
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4946
HacR_VPM_LVDT:VALr : 231
HacR_HPE1313A:0_Ch58 : -0.519531
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.783691
HacR_alignROLL : -0.302708
HacR_alignPITCH : -0.0338145
HacR_alignHPT : 2.60972
HacL_HPM_LVDT:VALr : -8326
HacL_VPM_LVDT:VALr : 2420
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.0112305
HacL_alignROLL : 0.331165
HacL_alignPITCH : -0.131612
HacL_alignHPT : 5.41113
Right Arm Angle Floor Angle : 59
Right Arm Angle Vernier : -64.5
Right Arm Scattering Angle : 58.8076
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.842
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 100
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88