• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 16:15:44 on October 5, 2000

    Entry number 49404

    keyword=Start_Run_1435_Tar=4He-10cm,Type=Cosmic,Pmom=2.105,Emom=0.7438,Ene=2384,Angle_e=58.81,Angle_h=16.842
    Beginning-of-run EPICS data for Run Number 1435 at Thu Oct  5 16:15:31 EDT 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=420,ps2=480,ps3=2070,ps4=92,ps5=1,ps6=65535,ps8=65535
    
    
    Right Arm Q1 power supply current        : 559.16
    Right Arm Q1 momentum                    : 0.743628
    Right Arm Q1 gauss meter                 : 0.014274
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 320.224
    Right Arm Q2 momentum                    : 0.744072
    Right Arm Q2 gauss meter                 : -0.16944
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 254.055
    Right Arm D1 momentum                    : 0.743801
    Right Arm D1 NMR                         : 0.276015
    Right Arm Q3 power supply current        : 295.94
    Right Arm Q3 momentum                    : 0.743738
    Right Arm Q3 gauss meter                 : -0.13314
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1583.65
    Left Arm Q1 momentum                      : 2.10498
    Left Arm Q1 gauss meter                   : -0.13409
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 906.372
    Left Arm Q2 momentum                      : 2.1049
    Left Arm Q2 gauss meter                   : 0.4783
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 716.552
    Left Arm D1 momentum                      : 2.10499
    Left Arm D1 NMR                           : 0.778897
    Left Arm Q3 power supply current          : 838.216
    Left Arm Q3 momentum                      : 2.10544
    Left Arm Q3 gauss meter                   : -0.4179
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 0.0310332
    Current on Unser monitor                : 0.212285
    Current on Upstream bcm                 : 0.0350901
    Current on Downstream bcm               : 0.0269762
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
     Current on IBC0L02 (source)            : 0.00142881
    Beam energy                             : 2391.63
    MBSY1c magnet current (amp)             : 0.0377197
     Radiator 5V Linear Supply              : 
     Radiator Encoder                       : 
    haBDSPOS                                 : 732017
    haL1_Fan_frequency_R                     : 65.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 243.6
    haSC200_6_Sensor_2_R                     : 219.78
    haSC200_6_Sensor_3_R                     : 0.23
    haSC200_6_Sensor_4_R                     : 36.1
    haHe_Omega_DPG_Sensor_R                  : 5.669
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.78
    haITC502_1_Sensor_3_R                    : 5.87
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 111.5
    haITC502_4_Sensor_3_R                    : 79.6
    haITC502_5_Sensor_1_R                    : 5.87
    haITC502_5_Sensor_2_R                    : 5.81
    haITC502_5_Sensor_3_R                    : 206.8
    haITC502_6_Sensor_1_R                    : 5.96
    haITC502_6_Sensor_2_R                    : 5.81
    haITC502_6_Sensor_3_R                    : 27.07
    Right Arm Arm Collimator                 : 0.614893
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4946
     HacR_VPM_LVDT:VALr                     : 231
     HacR_HPE1313A:0_Ch58                   : -0.519531
     HacR_HPE1313A:0_Ch55                   : 22.1191
     HacR_HPE1313A:0_Ch54                   : -0.783691
     HacR_alignROLL                         : -0.302708
     HacR_alignPITCH                        : -0.0338145
     HacR_alignHPT                          : 2.60972
     HacL_HPM_LVDT:VALr                     : -8326
     HacL_VPM_LVDT:VALr                     : 2420
     HacL_HPE1313A:0_Ch58                   : -0.149902
     HacL_HPE1313A:0_Ch55                   : 23.7793
     HacL_HPE1313A:0_Ch54                   : -0.0112305
     HacL_alignROLL                         : 0.331165
     HacL_alignPITCH                        : -0.131612
     HacL_alignHPT                          : 5.41113
    Right Arm Angle Floor Angle               : 59
    Right Arm Angle Vernier                   : -64.5
    Right Arm Scattering Angle                : 58.8076
    Left Arm Angle Floor Angle                 : 17
    Left Arm Angle Vernier                     : 10
    Left Arm Scattering Angle                  : 16.842
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 100
    Laser power  Hall A                      : 63
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88