    User name M Jones

    Log entry time 16:49:26 on October 5,2000

    Entry number 49406

    keyword=harp scan

    <\pre>
    harp scan. I redid the analysis of the harp bulls-eye scan.
    I get values of
    offset amp
    BPMA x -4.71e-4 1.11
    BPMA y 6.75e-4 1.07
    BPMB x 3.17e-4 0.95
    BPMB y 3.41e-4 0.99

    Below is a plot of Harp vs espace bpm values after using
    the above coefficients. The slope is about 1.0 with almost
    zero offset. The average difference between harp and espace
    values is less than 0.1mm for all bpm.
    The epics bpm data still needs to be calibrated.
    I added the new bpm coefficients to db_89044_e840_h840.
    I modified calib.dat on adaqs3 in the bpmcalib directory
    so that spot++ will have the same coefficients ( Remember
    the spot++ plots position at bpmB and use the same
    coordinate system as MCC with +x beam right. Espace
    use +x beam left)


    FIGURE 1