    User name adev

    Log entry time 00:16:48 on October 6, 2000

    Entry number 49410

    keyword=Start_Run_1437_Tar=carbon,Type=QuasiElastic,Pmom=2.105,Emom=0.7438,Ene=2384,Angle_e=58.81,Angle_h=16.842
    Beginning-of-run EPICS data for Run Number 1437 at Fri Oct  6 00:16:32 EDT 2000
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=2,ps2=20,ps3=7,ps4=1,ps5=1,ps6=65535,ps8=65535
    
    
    Right Arm Q1 power supply current        : 559.195
    Right Arm Q1 momentum                    : 0.743675
    Right Arm Q1 gauss meter                 : 0.014273
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 320.127
    Right Arm Q2 momentum                    : 0.743846
    Right Arm Q2 gauss meter                 : -0.1694
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 255.425
    Right Arm D1 momentum                    : 0.7438
    Right Arm D1 NMR                         : 0.276015
    Right Arm Q3 power supply current        : 295.93
    Right Arm Q3 momentum                    : 0.743712
    Right Arm Q3 gauss meter                 : -0.13318
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1583.54
    Left Arm Q1 momentum                      : 2.10484
    Left Arm Q1 gauss meter                   : -0.13406
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 906.404
    Left Arm Q2 momentum                      : 2.10498
    Left Arm Q2 gauss meter                   : 0.4783
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 716.56
    Left Arm D1 momentum                      : 2.105
    Left Arm D1 NMR                           : 0.7789
    Left Arm Q3 power supply current          : 838.1
    Left Arm Q3 momentum                      : 2.10515
    Left Arm Q3 gauss meter                   : -0.418
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 6.84767
    Current on Unser monitor                : 7.34281
    Current on Upstream bcm                 : 6.92843
    Current on Downstream bcm               : 6.76691
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
     Current on IBC0L02 (source)            : 6.95383
    Beam energy                             : 2391.63
    MBSY1c magnet current (amp)             : 99.5348
     Radiator 5V Linear Supply              : 
     Radiator Encoder                       : 
    haBDSPOS                                 : 732017
    haL1_Fan_frequency_R                     : 61.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 243.85
    haSC200_6_Sensor_2_R                     : 219.78
    haSC200_6_Sensor_3_R                     : 0.27
    haSC200_6_Sensor_4_R                     : 36.07
    haHe_Omega_DPG_Sensor_R                  : 5.666
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.78
    haITC502_1_Sensor_3_R                    : 5.87
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 113.7
    haITC502_4_Sensor_3_R                    : 81.4
    haITC502_5_Sensor_1_R                    : 5.86
    haITC502_5_Sensor_2_R                    : 5.8
    haITC502_5_Sensor_3_R                    : 212.4
    haITC502_6_Sensor_1_R                    : 5.92
    haITC502_6_Sensor_2_R                    : 5.81
    haITC502_6_Sensor_3_R                    : 27.17
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4935
     HacR_VPM_LVDT:VALr                     : 97
     HacR_HPE1313A:0_Ch58                   : -0.518066
     HacR_HPE1313A:0_Ch55                   : 22.4121
     HacR_HPE1313A:0_Ch54                   : -0.780762
     HacR_alignROLL                         : -0.298845
     HacR_alignPITCH                        : -0.0342825
     HacR_alignHPT                          : 2.59531
     HacL_HPM_LVDT:VALr                     : -8350
     HacL_VPM_LVDT:VALr                     : 2289
     HacL_HPE1313A:0_Ch58                   : -0.148926
     HacL_HPE1313A:0_Ch55                   : 24.0234
     HacL_HPE1313A:0_Ch54                   : -0.00927734
     HacL_alignROLL                         : 0.333407
     HacL_alignPITCH                        : -0.132858
     HacL_alignHPT                          : 5.43575
    Right Arm Angle Floor Angle               : 59
    Right Arm Angle Vernier                   : -64.5
    Right Arm Scattering Angle                : 58.8077
    Left Arm Angle Floor Angle                 : 17
    Left Arm Angle Vernier                     : 10
    Left Arm Scattering Angle                  : 16.8418
    Wien angle                               : 
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 40
    Laser power  Hall A                      : 63
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88