Main INDEX
Monthly INDEX
PREV
NEXT
User name Eric Voutier
Log entry time 00:18:24 on October 6,2000
Entry number 49411
keyword=Shift summary
New Baby-sitting shift: Eric Voutier
*******************
-# 18:00 The dipole of the left arm tripped and does not want to go back when
reseting the power supply; this one is always faulting. Tech. on call is coming.
-# 19:30 D_right is back
-# 20:15 Accelerator sweep starts
-# 20:55 Accelerator goes to Beam Permit
-# 22:15 Hall A goes to Power Permit
-# 23:05 MCC is sending beam in the hall...
-# 23:30 CW at 6uA
Final Harp scan to check the beam size yields
***************************************************************
Uncorrected Corrected Sigma Base
position position Width Width
Scanner #5 4ax: 491.0um 571.0um 170.0um
Scanner #5 4ay: -1538.00um -1448.00um 97.4um
Scanner #6 4bx: 363.00um 163.00um 129.0um
Scanner #6 4by: 15.00um -175.00um 112.2um
***************************************************************