Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:48:45 on October 6, 2000
Entry number 49421
keyword=Start_Run_1442_Tar=4He-10cm,Type=Elastic,Pmom=2.366,Emom=0.7438,Ene=2384,Angle_e=58.81,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1442 at Fri Oct 6 01:48:30 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=1000,ps3=20,ps4=40,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 559.09
Right Arm Q1 momentum : 0.743535
Right Arm Q1 gauss meter : 0.014267
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 320.202
Right Arm Q2 momentum : 0.74402
Right Arm Q2 gauss meter : -0.16944
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 255.423
Right Arm D1 momentum : 0.7438
Right Arm D1 NMR : 0.276015
Right Arm Q3 power supply current : 296.159
Right Arm Q3 momentum : 0.744289
Right Arm Q3 gauss meter : -0.13317
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1780.1
Left Arm Q1 momentum : 2.36611
Left Arm Q1 gauss meter : -0.15067
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1018.8
Left Arm Q2 momentum : 2.366
Left Arm Q2 gauss meter : 0.5376
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 812.16
Left Arm D1 momentum : 2.36601
Left Arm D1 NMR : 0.875591
Left Arm Q3 power supply current : 941.813
Left Arm Q3 momentum : 2.36598
Left Arm Q3 gauss meter : -0.4699
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 59.8487
Current on Unser monitor : 61.1607
Current on Upstream bcm : 60.7171
Current on Downstream bcm : 58.9803
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 60.8918
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.57
haSC200_6_Sensor_2_R : 221.01
haSC200_6_Sensor_3_R : 0.22
haSC200_6_Sensor_4_R : 36
haHe_Omega_DPG_Sensor_R : 5.575
haITC502_1_Sensor_1_R : 5.77
haITC502_1_Sensor_2_R : 5.75
haITC502_1_Sensor_3_R : 5.98
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 113.6
haITC502_4_Sensor_3_R : 81.7
haITC502_5_Sensor_1_R : 5.88
haITC502_5_Sensor_2_R : 5.77
haITC502_5_Sensor_3_R : 210.8
haITC502_6_Sensor_1_R : 6.01
haITC502_6_Sensor_2_R : 5.92
haITC502_6_Sensor_3_R : 27
Right Arm Arm Collimator : 0.614844
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4921
HacR_VPM_LVDT:VALr : 153
HacR_HPE1313A:0_Ch58 : -0.518555
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.782715
HacR_alignROLL : -0.30259
HacR_alignPITCH : -0.0348458
HacR_alignHPT : 2.58301
HacL_HPM_LVDT:VALr : -8353
HacL_VPM_LVDT:VALr : 2333
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.0102539
HacL_alignROLL :
HacL_alignPITCH : -0.131836
HacL_alignHPT : 5.44074
Right Arm Angle Floor Angle : 59
Right Arm Angle Vernier : -64.5
Right Arm Scattering Angle : 58.8077
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8418
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 214
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88