User name adev
Log entry time 03:23:57 on October 6, 2000
Entry number 49428
keyword=Start_Run_1444_Tar=4He-10cm,Type=Elastic,Pmom=2.366,Emom=1.657,Ene=2384,Angle_e=19.870,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1444 at Fri Oct 6 03:23:35 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=1200,ps3=20,ps4=50,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1246.04
Right Arm Q1 momentum : 1.65711
Right Arm Q1 gauss meter : 0.03137
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 713.241
Right Arm Q2 momentum : 1.65705
Right Arm Q2 gauss meter : -0.3757
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 571.497
Right Arm D1 momentum : 1.6571
Right Arm D1 NMR : 0.61493
Right Arm Q3 power supply current : 659.285
Right Arm Q3 momentum : 1.65687
Right Arm Q3 gauss meter : -0.2959
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1780.2
Left Arm Q1 momentum : 2.36625
Left Arm Q1 gauss meter : -0.1507
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1018.67
Left Arm Q2 momentum : 2.36632
Left Arm Q2 gauss meter : 0.5375
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 812.155
Left Arm D1 momentum : 2.366
Left Arm D1 NMR : 0.875586
Left Arm Q3 power supply current : 942.087
Left Arm Q3 momentum : 2.36635
Left Arm Q3 gauss meter : -0.4699
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 60.4941
Current on Unser monitor : 62.8366
Current on Upstream bcm : 61.22
Current on Downstream bcm : 59.7682
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 61.3478
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.43
haSC200_6_Sensor_2_R : 223.07
haSC200_6_Sensor_3_R : 0.18
haSC200_6_Sensor_4_R : 35.97
haHe_Omega_DPG_Sensor_R : 5.638
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 113.4
haITC502_4_Sensor_3_R : 82.5
haITC502_5_Sensor_1_R : 5.92
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 204.5
haITC502_6_Sensor_1_R : 6.16
haITC502_6_Sensor_2_R : 5.95
haITC502_6_Sensor_3_R : 26.89
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1194
HacR_VPM_LVDT:VALr : -573
HacR_HPE1313A:0_Ch58 : -0.537109
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.78125
HacR_alignROLL : -0.30056
HacR_alignPITCH : -0.0178583
HacR_alignHPT : -1.47353
HacL_HPM_LVDT:VALr : -8220
HacL_VPM_LVDT:VALr : 2020
HacL_HPE1313A:0_Ch58 : -0.150391
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.046875
HacL_alignROLL : 0.297699
HacL_alignPITCH : -0.131176
HacL_alignHPT : 5.30875
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -58.5
Right Arm Scattering Angle : 19.8698
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8427
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 218
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88