Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 03:50:19 on October 6, 2000
Entry number 49430
keyword=Start_Run_1445_Tar=4He-10cm,Type=Elastic,Pmom=2.366,Emom=1.657,Ene=2384,Angle_e=19.870,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1445 at Fri Oct 6 03:50:05 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=1200,ps3=20,ps4=50,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1246.04
Right Arm Q1 momentum : 1.65711
Right Arm Q1 gauss meter : 0.03137
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 713.169
Right Arm Q2 momentum : 1.65712
Right Arm Q2 gauss meter : -0.3757
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 571.464
Right Arm D1 momentum : 1.6571
Right Arm D1 NMR : 0.61493
Right Arm Q3 power supply current : 659.338
Right Arm Q3 momentum : 1.65701
Right Arm Q3 gauss meter : -0.2959
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1780.06
Left Arm Q1 momentum : 2.36606
Left Arm Q1 gauss meter : -0.15073
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1018.73
Left Arm Q2 momentum : 2.36584
Left Arm Q2 gauss meter : 0.5375
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 812.156
Left Arm D1 momentum : 2.366
Left Arm D1 NMR : 0.875587
Left Arm Q3 power supply current : 942.077
Left Arm Q3 momentum : 2.36632
Left Arm Q3 gauss meter : -0.4699
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 59.035
Current on Unser monitor : 61.5651
Current on Upstream bcm : 59.5465
Current on Downstream bcm : 58.5235
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 59.8948
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.37
haSC200_6_Sensor_2_R : 223.87
haSC200_6_Sensor_3_R : 0.12
haSC200_6_Sensor_4_R : 35.94
haHe_Omega_DPG_Sensor_R : 5.587
haITC502_1_Sensor_1_R : 5.81
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 113.4
haITC502_4_Sensor_3_R : 82.5
haITC502_5_Sensor_1_R : 5.92
haITC502_5_Sensor_2_R : 5.82
haITC502_5_Sensor_3_R : 204
haITC502_6_Sensor_1_R : 6.14
haITC502_6_Sensor_2_R : 5.96
haITC502_6_Sensor_3_R : 26.84
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -1195
HacR_VPM_LVDT:VALr : -552
HacR_HPE1313A:0_Ch58 : -0.535645
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.779785
HacR_alignROLL : -0.29914
HacR_alignPITCH : -0.0191382
HacR_alignHPT : -1.47322
HacL_HPM_LVDT:VALr : -8214
HacL_VPM_LVDT:VALr : 2019
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.0478516
HacL_alignROLL : 0.296694
HacL_alignPITCH : -0.130665
HacL_alignHPT : 5.30253
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -58.5
Right Arm Scattering Angle : 19.8698
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8427
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 214
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88