Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 09:43:42 on October 6, 2000
Entry number 49478
keyword=Start_Run_1467_Tar=4He-10cm,Type=pion_prod,Thcm=py-1f,Pmom=1.354,Emom=1.657,Ene=2384,Angle_e=19.870,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1467 at Fri Oct 6 09:43:24 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=4000,ps2=6000,ps3=12000,ps4=700,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1246.1
Right Arm Q1 momentum : 1.6572
Right Arm Q1 gauss meter : 0.03138
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 713.274
Right Arm Q2 momentum : 1.65736
Right Arm Q2 gauss meter : -0.3757
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 571.461
Right Arm D1 momentum : 1.6571
Right Arm D1 NMR : 0.61493
Right Arm Q3 power supply current : 659.159
Right Arm Q3 momentum : 1.65656
Right Arm Q3 gauss meter : -0.2958
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1018.43
Left Arm Q1 momentum : 1.3537
Left Arm Q1 gauss meter : -0.08633
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 583.061
Left Arm Q2 momentum : 1.35385
Left Arm Q2 gauss meter : 0.3081
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 452.525
Left Arm D1 momentum : 1.35399
Left Arm D1 NMR : 0.501167
Left Arm Q3 power supply current : 538.813
Left Arm Q3 momentum : 1.3534
Left Arm Q3 gauss meter : -0.2685
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 67.763
Current on Unser monitor : 69.6239
Current on Upstream bcm : 68.4221
Current on Downstream bcm : 67.1039
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 68.812
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.15
haSC200_6_Sensor_2_R : 223.95
haSC200_6_Sensor_3_R : 0.15
haSC200_6_Sensor_4_R : 36
haHe_Omega_DPG_Sensor_R : 5.682
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.03
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 114.7
haITC502_4_Sensor_3_R : 82.5
haITC502_5_Sensor_1_R : 5.94
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 198.9
haITC502_6_Sensor_1_R : 14.22
haITC502_6_Sensor_2_R : 5.97
haITC502_6_Sensor_3_R : 26.8
Right Arm Arm Collimator : 0.614844
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1196
HacR_VPM_LVDT:VALr : -459
HacR_HPE1313A:0_Ch58 : -0.529785
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.776855
HacR_alignROLL : -0.296301
HacR_alignPITCH : -0.025288
HacR_alignHPT : -1.47148
HacL_HPM_LVDT:VALr : -8194
HacL_VPM_LVDT:VALr : 2046
HacL_HPE1313A:0_Ch58 : -0.151367
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.0488281
HacL_alignROLL : 0.295613
HacL_alignPITCH : -0.130952
HacL_alignHPT : 5.28071
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -58.5
Right Arm Scattering Angle : 19.8698
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8429
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 240
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88