Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 11:45:59 on October 7, 2000
Entry number 49650
keyword=Start_Run_1543_Tar=4He-10cm,Type=pion_prod,Thcm=PY-1e,Pmom=1.559,Emom=1.4305,Ene=2384,Angle_e=26.888,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1543 at Sat Oct 7 11:45:46 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3500,ps2=5000,ps3=12000,ps4=700,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1075.62
Right Arm Q1 momentum : 1.43047
Right Arm Q1 gauss meter : 0.02716
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 615.665
Right Arm Q2 momentum : 1.43056
Right Arm Q2 gauss meter : -0.3244
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 490.371
Right Arm D1 momentum : 1.4305
Right Arm D1 NMR : 0.530841
Right Arm Q3 power supply current : 569.065
Right Arm Q3 momentum : 1.43014
Right Arm Q3 gauss meter : -0.2555
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1172.68
Left Arm Q1 momentum : 1.55872
Left Arm Q1 gauss meter : -0.0993
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 671.207
Left Arm Q2 momentum : 1.55849
Left Arm Q2 gauss meter : 0.3545
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 522.591
Left Arm D1 momentum : 1.55899
Left Arm D1 NMR : 0.57698
Left Arm Q3 power supply current : 620.7
Left Arm Q3 momentum : 1.55908
Left Arm Q3 gauss meter : -0.3095
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 60.925
Current on Unser monitor : 62.2934
Current on Upstream bcm : 61.7923
Current on Downstream bcm : 60.0576
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 61.9547
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.91
haSC200_6_Sensor_2_R : 223.75
haSC200_6_Sensor_3_R : 0.3
haSC200_6_Sensor_4_R : 36.17
haHe_Omega_DPG_Sensor_R : 5.616
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 180.7
haITC502_4_Sensor_3_R : 91.9
haITC502_5_Sensor_1_R : 5.99
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 194.5
haITC502_6_Sensor_1_R : 9.77
haITC502_6_Sensor_2_R : 5.96
haITC502_6_Sensor_3_R : 26.75
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4034
HacR_VPM_LVDT:VALr : -649
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.717285
HacR_alignROLL : -0.236295
HacR_alignPITCH : 0.0134374
HacR_alignHPT : 1.64234
HacL_HPM_LVDT:VALr : -8196
HacL_VPM_LVDT:VALr : 2132
HacL_HPE1313A:0_Ch58 : -0.153809
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.0356445
HacL_alignROLL : 0.30708
HacL_alignPITCH : -0.12731
HacL_alignHPT : 5.27718
Right Arm Angle Floor Angle : 26.5
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 26.8876
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8429
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 236
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88