Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:00:40 on October 8, 2000
Entry number 49728
keyword=Start_Run_1579_Tar=4He-10cm,Type=pion_prod,Thcm=PY-1e,Pmom=1.559,Emom=1.4305,Ene=2384,Angle_e=26.888,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1579 at Sun Oct 8 01:00:25 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3500,ps2=5000,ps3=12000,ps4=700,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1075.69
Right Arm Q1 momentum : 1.43056
Right Arm Q1 gauss meter : 0.02716
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 615.737
Right Arm Q2 momentum : 1.43072
Right Arm Q2 gauss meter : -0.3245
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 490.368
Right Arm D1 momentum : 1.4305
Right Arm D1 NMR : 0.530841
Right Arm Q3 power supply current : 569.1
Right Arm Q3 momentum : 1.43023
Right Arm Q3 gauss meter : -0.2555
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1172.68
Left Arm Q1 momentum : 1.55872
Left Arm Q1 gauss meter : -0.09933
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 671.511
Left Arm Q2 momentum : 1.55948
Left Arm Q2 gauss meter : 0.3546
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 522.597
Left Arm D1 momentum : 1.559
Left Arm D1 NMR : 0.576982
Left Arm Q3 power supply current : 620.655
Left Arm Q3 momentum : 1.55897
Left Arm Q3 gauss meter : -0.3096
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 60.9361
Current on Unser monitor : 61.6549
Current on Upstream bcm : 61.8319
Current on Downstream bcm : 60.0403
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 61.8584
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.86
haSC200_6_Sensor_2_R : 223.38
haSC200_6_Sensor_3_R : 0.33
haSC200_6_Sensor_4_R : 36.13
haHe_Omega_DPG_Sensor_R : 5.704
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 192.5
haITC502_4_Sensor_3_R : 89.7
haITC502_5_Sensor_1_R : 6.02
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 190.1
haITC502_6_Sensor_1_R : 11.64
haITC502_6_Sensor_2_R : 5.96
haITC502_6_Sensor_3_R : 26.7
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4038
HacR_VPM_LVDT:VALr : -646
HacR_HPE1313A:0_Ch58 : -0.569336
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.722656
HacR_alignROLL : -0.241958
HacR_alignPITCH : 0.0123541
HacR_alignHPT : 1.65116
HacL_HPM_LVDT:VALr : -8194
HacL_VPM_LVDT:VALr : 2129
HacL_HPE1313A:0_Ch58 : -0.153809
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0361328
HacL_alignROLL : 0.30654
HacL_alignPITCH : -0.127672
HacL_alignHPT : 5.27434
Right Arm Angle Floor Angle : 26.5
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 26.8875
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8429
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 245
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88