User name adev
Log entry time 10:40:06 on October 8, 2000
Entry number 49769
keyword=Start_Run_1595_Tar=4He-10cm,Type=pion_prod,Thcm=PY-1e,Pmom=1.559,Emom=1.4305,Ene=2384,Angle_e=26.888,Angle_h=16.842
Beginning-of-run EPICS data for Run Number 1595 at Sun Oct 8 10:39:51 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3500,ps2=5000,ps3=12000,ps4=700,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1075.69
Right Arm Q1 momentum : 1.43056
Right Arm Q1 gauss meter : 0.02716
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 615.662
Right Arm Q2 momentum : 1.43055
Right Arm Q2 gauss meter : -0.3243
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 490.37
Right Arm D1 momentum : 1.4305
Right Arm D1 NMR : 0.530841
Right Arm Q3 power supply current : 569.299
Right Arm Q3 momentum : 1.43073
Right Arm Q3 gauss meter : -0.2556
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1172.71
Left Arm Q1 momentum : 1.55877
Left Arm Q1 gauss meter : -0.09931
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 671.471
Left Arm Q2 momentum : 1.55939
Left Arm Q2 gauss meter : 0.3546
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 522.584
Left Arm D1 momentum : 1.559
Left Arm D1 NMR : 0.576982
Left Arm Q3 power supply current : 620.732
Left Arm Q3 momentum : 1.55916
Left Arm Q3 gauss meter : -0.3096
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 69.7289
Current on Unser monitor : 70.0175
Current on Upstream bcm : 69.714
Current on Downstream bcm : 69.7439
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 69.5047
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
Radiator 5V Linear Supply :
Radiator Encoder :
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.55
haSC200_6_Sensor_2_R : 224.18
haSC200_6_Sensor_3_R : 0.8
haSC200_6_Sensor_4_R : 36.38
haHe_Omega_DPG_Sensor_R : 5.613
haITC502_1_Sensor_1_R : 5.79
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 6.03
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 193.7
haITC502_4_Sensor_3_R : 90.3
haITC502_5_Sensor_1_R : 6.03
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 190.1
haITC502_6_Sensor_1_R : 13.34
haITC502_6_Sensor_2_R : 6.01
haITC502_6_Sensor_3_R : 26.73
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4069
HacR_VPM_LVDT:VALr : -726
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.71582
HacR_alignROLL : -0.234142
HacR_alignPITCH : 0.00965005
HacR_alignHPT : 1.68253
HacL_HPM_LVDT:VALr : -8229
HacL_VPM_LVDT:VALr : 2050
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.0366211
HacL_alignROLL : 0.306455
HacL_alignPITCH : -0.131101
HacL_alignHPT : 5.31573
Right Arm Angle Floor Angle : 26.5
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 26.8873
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 16.8426
Wien angle :
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 270
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88