User name adev
Log entry time 21:58:31 on October 8, 2000
Entry number 49840
keyword=Start_Run_1625_Tar=4He-10cm,Type=Elastic,Pmom=2.35974,Emom=1.4305,Ene=2384,Angle_e=26.888,Angle_h=17.726
Beginning-of-run EPICS data for Run Number 1625 at Sun Oct 8 21:58:17 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=800,ps2=1100,ps3=8,ps4=35,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1075.62
Right Arm Q1 momentum : 1.43047
Right Arm Q1 gauss meter : 0.02716
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 615.67
Right Arm Q2 momentum : 1.43057
Right Arm Q2 gauss meter : -0.3244
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 490.37
Right Arm D1 momentum : 1.4305
Right Arm D1 NMR : 0.530841
Right Arm Q3 power supply current : 569.127
Right Arm Q3 momentum : 1.4303
Right Arm Q3 gauss meter : -0.2555
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1775.27
Left Arm Q1 momentum : 2.35969
Left Arm Q1 gauss meter : -0.15028
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1016.11
Left Arm Q2 momentum : 2.35975
Left Arm Q2 gauss meter : 0.5361
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 809.826
Left Arm D1 momentum : 2.35975
Left Arm D1 NMR : 0.873266
Left Arm Q3 power supply current : 939.528
Left Arm Q3 momentum : 2.35992
Left Arm Q3 gauss meter : -0.4687
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 63.9057
Current on Unser monitor : 64.0702
Current on Upstream bcm : 64.2665
Current on Downstream bcm : 63.5448
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 63.4058
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.8
haSC200_6_Sensor_2_R : 223.96
haSC200_6_Sensor_3_R : 1.06
haSC200_6_Sensor_4_R : 36.5
haHe_Omega_DPG_Sensor_R : 5.622
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 197.8
haITC502_4_Sensor_3_R : 92.4
haITC502_5_Sensor_1_R : 6.05
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 193.5
haITC502_6_Sensor_1_R : 12.88
haITC502_6_Sensor_2_R : 6.17
haITC502_6_Sensor_3_R : 26.81
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -4083
HacR_VPM_LVDT:VALr : -785
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.710938
HacR_alignROLL : -0.228356
HacR_alignPITCH : 0.00970408
HacR_alignHPT : 1.69378
HacL_HPM_LVDT:VALr : -7721
HacL_VPM_LVDT:VALr : 1874
HacL_HPE1313A:0_Ch58 : -0.15918
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.0952148
HacL_alignROLL : 0.251996
HacL_alignPITCH : -0.102984
HacL_alignHPT : 4.77313
Right Arm Angle Floor Angle : 26.5
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 26.8873
Left Arm Angle Floor Angle : 18
Left Arm Angle Vernier : -10.8
Left Arm Scattering Angle : 17.7264
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 280
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88