User name adev
Log entry time 22:37:34 on October 8, 2000
Entry number 49844
keyword=Start_Run_1627_Tar=4He-10cm,Type=Elastic,Pmom=2.35974,Emom=1.4305,Ene=2384,Angle_e=26.888,Angle_h=17.726
Beginning-of-run EPICS data for Run Number 1627 at Sun Oct 8 22:37:20 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=800,ps2=1100,ps3=8,ps4=35,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1075.69
Right Arm Q1 momentum : 1.43056
Right Arm Q1 gauss meter : 0.02715
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 615.699
Right Arm Q2 momentum : 1.43064
Right Arm Q2 gauss meter : -0.3244
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 490.372
Right Arm D1 momentum : 1.4305
Right Arm D1 NMR : 0.530841
Right Arm Q3 power supply current : 569.027
Right Arm Q3 momentum : 1.43004
Right Arm Q3 gauss meter : -0.2555
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1775.31
Left Arm Q1 momentum : 2.35974
Left Arm Q1 gauss meter : -0.15031
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1015.92
Left Arm Q2 momentum : 2.35932
Left Arm Q2 gauss meter : 0.5361
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 809.824
Left Arm D1 momentum : 2.35975
Left Arm D1 NMR : 0.873266
Left Arm Q3 power supply current : 939.446
Left Arm Q3 momentum : 2.35971
Left Arm Q3 gauss meter : -0.4687
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 64.208
Current on Unser monitor : 64.39
Current on Upstream bcm : 64.2326
Current on Downstream bcm : 64.1833
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 63.9424
Beam energy : 2391.63
MBSY1c magnet current (amp) : 99.5348
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.8
haSC200_6_Sensor_2_R : 224.16
haSC200_6_Sensor_3_R : 1.06
haSC200_6_Sensor_4_R : 36.48
haHe_Omega_DPG_Sensor_R : 5.713
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.03
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 198.2
haITC502_4_Sensor_3_R : 92.9
haITC502_5_Sensor_1_R : 6.05
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 192
haITC502_6_Sensor_1_R : 8.62
haITC502_6_Sensor_2_R : 6.17
haITC502_6_Sensor_3_R : 26.77
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -4085
HacR_VPM_LVDT:VALr : -789
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.710938
HacR_alignROLL : -0.22891
HacR_alignPITCH : 0.00887224
HacR_alignHPT : 1.69634
HacL_HPM_LVDT:VALr : -7723
HacL_VPM_LVDT:VALr : 1867
HacL_HPE1313A:0_Ch58 : -0.15918
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.0952148
HacL_alignROLL : 0.252513
HacL_alignPITCH : -0.103058
HacL_alignHPT : 4.77512
Right Arm Angle Floor Angle : 26.5
Right Arm Angle Vernier : 35
Right Arm Scattering Angle : 26.8872
Left Arm Angle Floor Angle : 18
Left Arm Angle Vernier : -10.8
Left Arm Scattering Angle : 17.7264
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 280
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88