User name adev
Log entry time 12:55:03 on October 9, 2000
Entry number 49902
keyword=Start_Run_1651_Tar=4He-10cm,Type=Elastic,Pmom=3.1467,Emom=1.4189,Ene=3.175,Angle_e=39.561,Angle_h=13.995
Beginning-of-run EPICS data for Run Number 1651 at Mon Oct 9 12:54:39 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=3,ps2=36,ps3=1,ps4=1,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1066.97
Right Arm Q1 momentum : 1.41897
Right Arm Q1 gauss meter : 0.02694
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 610.652
Right Arm Q2 momentum : 1.41891
Right Arm Q2 gauss meter : -0.3218
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 486.202
Right Arm D1 momentum : 1.4189
Right Arm D1 NMR : 0.526537
Right Arm Q3 power supply current : 564.716
Right Arm Q3 momentum : 1.41921
Right Arm Q3 gauss meter : -0.2534
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2367.47
Left Arm Q1 momentum : 3.14684
Left Arm Q1 gauss meter : -0.20048
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1354.88
Left Arm Q2 momentum : 3.1465
Left Arm Q2 gauss meter : 0.7141
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1106.71
Left Arm D1 momentum : 3.14669
Left Arm D1 NMR : 1.16527
Left Arm Q3 power supply current : 1252.78
Left Arm Q3 momentum : 3.14674
Left Arm Q3 gauss meter : -0.6249
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 10.4477
Current on Unser monitor : 9.97967
Current on Upstream bcm : 10.4271
Current on Downstream bcm : 10.4683
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 10.4972
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 244.23
haSC200_6_Sensor_2_R : 220.37
haSC200_6_Sensor_3_R : 1.25
haSC200_6_Sensor_4_R : 36.63
haHe_Omega_DPG_Sensor_R : 5.627
haITC502_1_Sensor_1_R : 5.78
haITC502_1_Sensor_2_R : 5.77
haITC502_1_Sensor_3_R : 5.88
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 203.6
haITC502_4_Sensor_3_R : 92.4
haITC502_5_Sensor_1_R : 6
haITC502_5_Sensor_2_R : 5.79
haITC502_5_Sensor_3_R : 193.8
haITC502_6_Sensor_1_R : 6.16
haITC502_6_Sensor_2_R : 5.96
haITC502_6_Sensor_3_R : 26.83
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -5084
HacR_VPM_LVDT:VALr : -185
HacR_HPE1313A:0_Ch58 : -0.54248
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.887695
HacR_alignROLL : -0.407065
HacR_alignPITCH : -0.0134523
HacR_alignHPT : 2.88478
HacL_HPM_LVDT:VALr : -7216
HacL_VPM_LVDT:VALr : 1607
HacL_HPE1313A:0_Ch58 : -0.201172
HacL_HPE1313A:0_Ch55 : 24.0234
HacL_HPE1313A:0_Ch54 : 0.0200195
HacL_alignROLL : 0.360833
HacL_alignPITCH : -0.0861296
HacL_alignHPT : 4.15663
Right Arm Angle Floor Angle : 39
Right Arm Angle Vernier : 66.5
Right Arm Scattering Angle : 39.5607
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 35
Left Arm Scattering Angle : 13.9946
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 98
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88