User name adev
Log entry time 15:16:49 on October 9, 2000
Entry number 49918
keyword=Start_Run_1659_Tar=4He-10cm,Type=QuasiElastic,Pmom=2.372,Emom=1.4189,Ene=3.175,Angle_e=39.561,Angle_h=18.622
Beginning-of-run EPICS data for Run Number 1659 at Mon Oct 9 15:16:38 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=230,ps2=732,ps3=729,ps4=50,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1066.97
Right Arm Q1 momentum : 1.41897
Right Arm Q1 gauss meter : 0.02694
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 610.641
Right Arm Q2 momentum : 1.41888
Right Arm Q2 gauss meter : -0.3217
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 486.202
Right Arm D1 momentum : 1.4189
Right Arm D1 NMR : 0.526537
Right Arm Q3 power supply current : 564.589
Right Arm Q3 momentum : 1.41889
Right Arm Q3 gauss meter : -0.2535
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 2.37188
Left Arm Q1 gauss meter : -0.15119
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1021.32
Left Arm Q2 momentum : 2.37186
Left Arm Q2 gauss meter : 0.5388
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 812.777
Left Arm D1 momentum : 2.37198
Left Arm D1 NMR : 0.877806
Left Arm Q3 power supply current : 944.413
Left Arm Q3 momentum : 2.37219
Left Arm Q3 gauss meter : -0.4711
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 60.3223
Current on Unser monitor : 60.4845
Current on Upstream bcm : 60.3112
Current on Downstream bcm : 60.3334
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 60.3176
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 244.33
haSC200_6_Sensor_2_R : 224.18
haSC200_6_Sensor_3_R : 1.31
haSC200_6_Sensor_4_R : 36.68
haHe_Omega_DPG_Sensor_R : 5.694
haITC502_1_Sensor_1_R : 5.81
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 204.6
haITC502_4_Sensor_3_R : 93.8
haITC502_5_Sensor_1_R : 6.06
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 189.8
haITC502_6_Sensor_1_R : 10.09
haITC502_6_Sensor_2_R : 6.29
haITC502_6_Sensor_3_R : 26.75
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617188
HacR_HPM_LVDT:VALr : -5110
HacR_VPM_LVDT:VALr : -154
HacR_HPE1313A:0_Ch58 : -0.541504
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.889648
HacR_alignROLL : -0.410079
HacR_alignPITCH : -0.0147326
HacR_alignHPT : 2.91536
HacL_HPM_LVDT:VALr : -7134
HacL_VPM_LVDT:VALr : 1958
HacL_HPE1313A:0_Ch58 : -0.152832
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.129395
HacL_alignROLL : 0.221512
HacL_alignPITCH : -0.109105
HacL_alignHPT : 4.13188
Right Arm Angle Floor Angle : 39
Right Arm Angle Vernier : 66.5
Right Arm Scattering Angle : 39.5605
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6215
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 255
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88