User name adev
Log entry time 23:49:32 on October 9, 2000
Entry number 49961
keyword=Start_Run_1676_Tar=4He-10cm,Type=Other,Pmom=2.517,Emom=1.1046,Ene=3.175,Angle_e=51.479,Angle_h=18.622
Beginning-of-run EPICS data for Run Number 1676 at Mon Oct 9 23:49:22 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=10,ps2=220,ps3=28,ps4=10,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 830.55
Right Arm Q1 momentum : 1.10455
Right Arm Q1 gauss meter : 0.02105
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 475.387
Right Arm Q2 momentum : 1.10461
Right Arm Q2 gauss meter : -0.2507
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 377.499
Right Arm D1 momentum : 1.1046
Right Arm D1 NMR :
Right Arm Q3 power supply current : 439.547
Right Arm Q3 momentum : 1.10464
Right Arm Q3 gauss meter : -0.19729
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1893.64
Left Arm Q1 momentum : 2.51703
Left Arm Q1 gauss meter : -0.16036
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1083.8
Left Arm Q2 momentum : 2.51695
Left Arm Q2 gauss meter : 0.5717
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 866.919
Left Arm D1 momentum : 2.51701
Left Arm D1 NMR : 0.931619
Left Arm Q3 power supply current : 1002.1
Left Arm Q3 momentum : 2.51709
Left Arm Q3 gauss meter : -0.4998
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 20.6017
Current on Unser monitor : 20.5618
Current on Upstream bcm : 20.6073
Current on Downstream bcm : 20.596
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 20.5293
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 244.39
haSC200_6_Sensor_2_R : 222.26
haSC200_6_Sensor_3_R : 1.4
haSC200_6_Sensor_4_R : 36.75
haHe_Omega_DPG_Sensor_R : 5.645
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.93
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 213.6
haITC502_4_Sensor_3_R : 100
haITC502_5_Sensor_1_R : 6.04
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 198.5
haITC502_6_Sensor_1_R : 8.65
haITC502_6_Sensor_2_R : 6.05
haITC502_6_Sensor_3_R : 26.86
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -5174
HacR_VPM_LVDT:VALr : -325
HacR_HPE1313A:0_Ch58 : -0.536621
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.806152
HacR_alignROLL : -0.324562
HacR_alignPITCH : -0.0185894
HacR_alignHPT : 2.91225
HacL_HPM_LVDT:VALr : -7145
HacL_VPM_LVDT:VALr : 2108
HacL_HPE1313A:0_Ch58 : -0.149414
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.118652
HacL_alignROLL : 0.231234
HacL_alignPITCH : -0.111725
HacL_alignHPT : 4.13947
Right Arm Angle Floor Angle : 51
Right Arm Angle Vernier : 52.4
Right Arm Scattering Angle : 51.4793
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6215
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 142
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88