Log entry time 00:31:53 on October 10, 2000
Entry number 49965
keyword=Start_Run_1677_Tar=4He-10cm,Type=Other,Pmom=2.517,Emom=1.1046,Ene=3.175,Angle_e=51.479,Angle_h=18.622
Beginning-of-run EPICS data for Run Number 1677 at Tue Oct 10 00:31:44 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=110,ps2=400,ps3=300,ps4=15,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 830.62
Right Arm Q1 momentum : 1.10464
Right Arm Q1 gauss meter : 0.02105
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 475.375
Right Arm Q2 momentum : 1.10457
Right Arm Q2 gauss meter : -0.2507
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 377.491
Right Arm D1 momentum : 1.1046
Right Arm D1 NMR : 0.409903
Right Arm Q3 power supply current : 439.545
Right Arm Q3 momentum : 1.10464
Right Arm Q3 gauss meter : -0.19728
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1980.82
Left Arm Q1 momentum : 2.63291
Left Arm Q1 gauss meter : -0.16775
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1133.83
Left Arm Q2 momentum : 2.63313
Left Arm Q2 gauss meter : 0.598
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 910.414
Left Arm D1 momentum : 2.63301
Left Arm D1 NMR : 0.974662
Left Arm Q3 power supply current : 1048.1
Left Arm Q3 momentum : 2.63263
Left Arm Q3 gauss meter : -0.5228
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 61.6203
Current on Unser monitor : 61.1942
Current on Upstream bcm : 61.6273
Current on Downstream bcm : 61.6134
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 61.4857
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 244.32
haSC200_6_Sensor_2_R : 224.2
haSC200_6_Sensor_3_R : 1.36
haSC200_6_Sensor_4_R : 36.73
haHe_Omega_DPG_Sensor_R : 5.595
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 6.02
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 214.5
haITC502_4_Sensor_3_R : 101.3
haITC502_5_Sensor_1_R : 6.06
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 194.5
haITC502_6_Sensor_1_R : 8.43
haITC502_6_Sensor_2_R : 6.11
haITC502_6_Sensor_3_R : 26.81
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -5177
HacR_VPM_LVDT:VALr : -316
HacR_HPE1313A:0_Ch58 : -0.535645
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.80957
HacR_alignROLL : -0.328072
HacR_alignPITCH : -0.0194207
HacR_alignHPT : 2.91758
HacL_HPM_LVDT:VALr : -7146
HacL_VPM_LVDT:VALr : 2117
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.119629
HacL_alignROLL : 0.23035
HacL_alignPITCH : -0.111725
HacL_alignHPT : 4.14104
Right Arm Angle Floor Angle : 51
Right Arm Angle Vernier : 52.4
Right Arm Scattering Angle : 51.4793
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6215
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 262
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88