Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:26:43 on October 10, 2000
Entry number 49975
keyword=Start_Run_1682_Tar=4He-10cm,Type=pion_prod,Thcm=PY_2a,Pmom=2.633,Emom=1.1046,Ene=3.175,Angle_e=51.479,Angle_h=18.622
Beginning-of-run EPICS data for Run Number 1682 at Tue Oct 10 01:26:30 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=470,ps2=1500,ps3=1270,ps4=135,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 830.62
Right Arm Q1 momentum : 1.10464
Right Arm Q1 gauss meter : 0.02105
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 475.367
Right Arm Q2 momentum : 1.10459
Right Arm Q2 gauss meter : -0.2508
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 377.498
Right Arm D1 momentum : 1.1046
Right Arm D1 NMR : 0.409904
Right Arm Q3 power supply current : 439.579
Right Arm Q3 momentum : 1.10472
Right Arm Q3 gauss meter : -0.19728
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1980.86
Left Arm Q1 momentum : 2.63296
Left Arm Q1 gauss meter : -0.16775
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1133.79
Left Arm Q2 momentum : 2.63305
Left Arm Q2 gauss meter : 0.5981
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 910.412
Left Arm D1 momentum : 2.633
Left Arm D1 NMR : 0.974661
Left Arm Q3 power supply current : 1048.31
Left Arm Q3 momentum : 2.63316
Left Arm Q3 gauss meter : -0.5229
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 90.6884
Current on Unser monitor : 89.2969
Current on Upstream bcm : 90.5052
Current on Downstream bcm : 90.8717
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 90.4751
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 244.32
haSC200_6_Sensor_2_R : 223.93
haSC200_6_Sensor_3_R : 1.38
haSC200_6_Sensor_4_R : 36.77
haHe_Omega_DPG_Sensor_R : 5.553
haITC502_1_Sensor_1_R : 5.77
haITC502_1_Sensor_2_R : 5.75
haITC502_1_Sensor_3_R : 6.06
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 215.6
haITC502_4_Sensor_3_R : 102.2
haITC502_5_Sensor_1_R : 6.06
haITC502_5_Sensor_2_R : 5.77
haITC502_5_Sensor_3_R : 191.9
haITC502_6_Sensor_1_R : 10.56
haITC502_6_Sensor_2_R : 6.22
haITC502_6_Sensor_3_R : 26.8
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -5175
HacR_VPM_LVDT:VALr : -321
HacR_HPE1313A:0_Ch58 : -0.534668
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.811523
HacR_alignROLL : -0.329986
HacR_alignPITCH : -0.020834
HacR_alignHPT : 2.91756
HacL_HPM_LVDT:VALr : -7146
HacL_VPM_LVDT:VALr : 2111
HacL_HPE1313A:0_Ch58 : -0.150391
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.118652
HacL_alignROLL : 0.231308
HacL_alignPITCH : -0.111363
HacL_alignHPT : 4.14282
Right Arm Angle Floor Angle : 51
Right Arm Angle Vernier : 52.4
Right Arm Scattering Angle : 51.4793
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6215
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 362
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88