Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:45:07 on October 10, 2000
Entry number 49977
keyword=Start_Run_1683_Tar=4He-10cm,Type=pion_prod,Thcm=PY_2a,Pmom=2.633,Emom=1.1046,Ene=3.175,Angle_e=51.479,Angle_h=18.622
Beginning-of-run EPICS data for Run Number 1683 at Tue Oct 10 01:44:54 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=470,ps2=1500,ps3=1270,ps4=135,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 830.655
Right Arm Q1 momentum : 1.10469
Right Arm Q1 gauss meter : 0.02103
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 475.372
Right Arm Q2 momentum : 1.10457
Right Arm Q2 gauss meter : -0.2508
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 377.497
Right Arm D1 momentum : 1.1046
Right Arm D1 NMR : 0.409904
Right Arm Q3 power supply current : 439.584
Right Arm Q3 momentum : 1.10474
Right Arm Q3 gauss meter : -0.1973
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1980.86
Left Arm Q1 momentum : 2.63296
Left Arm Q1 gauss meter : -0.16774
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1133.63
Left Arm Q2 momentum : 2.63268
Left Arm Q2 gauss meter : 0.598
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 910.413
Left Arm D1 momentum : 2.633
Left Arm D1 NMR : 0.974661
Left Arm Q3 power supply current : 1048.27
Left Arm Q3 momentum : 2.63305
Left Arm Q3 gauss meter : -0.5229
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 90.4227
Current on Unser monitor : 90.3053
Current on Upstream bcm : 90.4247
Current on Downstream bcm : 90.4208
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 90.2202
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 244.35
haSC200_6_Sensor_2_R : 226.05
haSC200_6_Sensor_3_R : 1.4
haSC200_6_Sensor_4_R : 36.72
haHe_Omega_DPG_Sensor_R : 5.661
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.1
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 216
haITC502_4_Sensor_3_R : 102.5
haITC502_5_Sensor_1_R : 6.09
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 191.5
haITC502_6_Sensor_1_R : 13.59
haITC502_6_Sensor_2_R : 6.21
haITC502_6_Sensor_3_R : 26.77
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -5177
HacR_VPM_LVDT:VALr : -321
HacR_HPE1313A:0_Ch58 : -0.535156
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.811035
HacR_alignROLL : -0.330479
HacR_alignPITCH : -0.020834
HacR_alignHPT : 2.91979
HacL_HPM_LVDT:VALr : -7146
HacL_VPM_LVDT:VALr : 2113
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 24.2676
HacL_HPE1313A:0_Ch54 : -0.117676
HacL_alignROLL : 0.232266
HacL_alignPITCH : -0.111873
HacL_alignHPT : 4.14236
Right Arm Angle Floor Angle : 51
Right Arm Angle Vernier : 52.4
Right Arm Scattering Angle : 51.4792
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6215
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 362
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88