Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 18:22:30 on October 10, 2000
Entry number 50025
keyword=Start_Run_1701_Tar=4He-10cm,Type=pion_prod,Thcm=PY_2f,Pmom=1.689,Emom=2.1538,Ene=3.1704,Angle_e=19.047,Angle_h=18.623
Beginning-of-run EPICS data for Run Number 1701 at Tue Oct 10 18:22:17 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=350,ps2=900,ps3=800,ps4=50,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1619.52
Right Arm Q1 momentum : 2.1538
Right Arm Q1 gauss meter : 0.04068
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 926.914
Right Arm Q2 momentum : 2.15377
Right Arm Q2 gauss meter : -0.4879
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 752.06
Right Arm D1 momentum : 2.1538
Right Arm D1 NMR : 0.799249
Right Arm Q3 power supply current : 857.043
Right Arm Q3 momentum : 2.15387
Right Arm Q3 gauss meter : -0.3844
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1270.6
Left Arm Q1 momentum : 1.68889
Left Arm Q1 gauss meter : -0.1077
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 727.336
Left Arm Q2 momentum : 1.68912
Left Arm Q2 gauss meter : 0.3841
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 567.192
Left Arm D1 momentum : 1.68899
Left Arm D1 NMR : 0.625054
Left Arm Q3 power supply current : 672.519
Left Arm Q3 momentum : 1.68924
Left Arm Q3 gauss meter : -0.3353
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0289889
Current on Unser monitor : 0.498699
Current on Upstream bcm : 0.0301954
Current on Downstream bcm : 0.0278102
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 3174.61
MBSY1c magnet current (amp) : 0.0377197
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.9
haSC200_6_Sensor_2_R : 220.96
haSC200_6_Sensor_3_R : 1.01
haSC200_6_Sensor_4_R : 36.52
haHe_Omega_DPG_Sensor_R : 5.63
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.88
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 230.8
haITC502_4_Sensor_3_R : 109
haITC502_5_Sensor_1_R : 6.04
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 190.2
haITC502_6_Sensor_1_R : 7.55
haITC502_6_Sensor_2_R : 5.95
haITC502_6_Sensor_3_R : 26.7
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1241
HacR_VPM_LVDT:VALr : -534
HacR_HPE1313A:0_Ch58 : -0.521973
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.763672
HacR_alignROLL : -0.294173
HacR_alignPITCH : -0.0309588
HacR_alignHPT : -1.41785
HacL_HPM_LVDT:VALr : -7002
HacL_VPM_LVDT:VALr : 1966
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 24.0234
HacL_HPE1313A:0_Ch54 : -0.152344
HacL_alignROLL : 0.200524
HacL_alignPITCH : -0.11063
HacL_alignHPT : 3.98999
Right Arm Angle Floor Angle : 18.5
Right Arm Angle Vernier : 59
Right Arm Scattering Angle : 19.0467
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6225
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 188
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88