User name adev
Log entry time 21:33:14 on October 10, 2000
Entry number 50040
keyword=Start_Run_1708_Tar=4He-10cm,Type=Other,Pmom=1.689,Emom=2.1538,Ene=3.1704,Angle_e=19.047,Angle_h=18.623
Beginning-of-run EPICS data for Run Number 1708 at Tue Oct 10 21:33:03 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=1000,ps5=1000,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1619.59
Right Arm Q1 momentum : 2.1539
Right Arm Q1 gauss meter : 0.04068
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 926.911
Right Arm Q2 momentum : 2.15377
Right Arm Q2 gauss meter : -0.4878
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 752.063
Right Arm D1 momentum : 2.1538
Right Arm D1 NMR : 0.799249
Right Arm Q3 power supply current : 857.122
Right Arm Q3 momentum : 2.15407
Right Arm Q3 gauss meter : -0.3843
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1270.6
Left Arm Q1 momentum : 1.68889
Left Arm Q1 gauss meter : -0.10769
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 727.534
Left Arm Q2 momentum : 1.68958
Left Arm Q2 gauss meter : 0.3841
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 567.189
Left Arm D1 momentum : 1.68899
Left Arm D1 NMR : 0.625054
Left Arm Q3 power supply current : 672.492
Left Arm Q3 momentum : 1.68917
Left Arm Q3 gauss meter : -0.3353
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 16.5993
Current on Unser monitor : 16.4202
Current on Upstream bcm : 16.6119
Current on Downstream bcm : 16.5866
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 16.6427
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 62
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.28
haSC200_6_Sensor_2_R : 221.84
haSC200_6_Sensor_3_R : 1.03
haSC200_6_Sensor_4_R : 36.58
haHe_Omega_DPG_Sensor_R : 5.696
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.92
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 232.5
haITC502_4_Sensor_3_R : 109.4
haITC502_5_Sensor_1_R : 6.05
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 190
haITC502_6_Sensor_1_R : 6.6
haITC502_6_Sensor_2_R : 6.12
haITC502_6_Sensor_3_R : 26.66
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -1238
HacR_VPM_LVDT:VALr : -661
HacR_HPE1313A:0_Ch58 : -0.522461
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.76709
HacR_alignROLL : -0.285989
HacR_alignPITCH : -0.0317416
HacR_alignHPT : -1.43259
HacL_HPM_LVDT:VALr : -7015
HacL_VPM_LVDT:VALr : 1897
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 24.1211
HacL_HPE1313A:0_Ch54 : -0.151855
HacL_alignROLL : 0.200671
HacL_alignPITCH : -0.111651
HacL_alignHPT : 4.00892
Right Arm Angle Floor Angle : 18.5
Right Arm Angle Vernier : 59
Right Arm Scattering Angle : 19.0468
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6224
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 130
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88