User name adev
Log entry time 17:10:53 on October 11, 2000
Entry number 50104
keyword=Start_Run_1734_Tar=dum-10cm,Type=Other,Pmom=1.689,Emom=2.1538,Ene=3.1704,Angle_e=19.047,Angle_h=18.623
Beginning-of-run EPICS data for Run Number 1734 at Wed Oct 11 17:10:44 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=50,ps2=270,ps3=128,ps4=5,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1619.59
Right Arm Q1 momentum : 2.1539
Right Arm Q1 gauss meter : 0.04067
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 926.93
Right Arm Q2 momentum : 2.15381
Right Arm Q2 gauss meter : -0.4878
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 752.068
Right Arm D1 momentum : 2.1538
Right Arm D1 NMR : 0.79925
Right Arm Q3 power supply current : 856.944
Right Arm Q3 momentum : 2.15362
Right Arm Q3 gauss meter : -0.3842
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1270.6
Left Arm Q1 momentum : 1.68889
Left Arm Q1 gauss meter : -0.10767
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 727.262
Left Arm Q2 momentum : 1.68895
Left Arm Q2 gauss meter : 0.3841
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 567.19
Left Arm D1 momentum : 1.68901
Left Arm D1 NMR : 0.62506
Left Arm Q3 power supply current : 672.411
Left Arm Q3 momentum : 1.68897
Left Arm Q3 gauss meter : -0.3353
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 29.9502
Current on Unser monitor : 30.4749
Current on Upstream bcm : 30.0306
Current on Downstream bcm : 29.8698
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 29.9622
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 2.11542e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.6
haSC200_6_Sensor_2_R : 229.49
haSC200_6_Sensor_3_R : 1.28
haSC200_6_Sensor_4_R : 36.8
haHe_Omega_DPG_Sensor_R : 5.784
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.88
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 231.6
haITC502_4_Sensor_3_R : 101.5
haITC502_5_Sensor_1_R : 6.06
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 190.2
haITC502_6_Sensor_1_R : 8.95
haITC502_6_Sensor_2_R : 5.92
haITC502_6_Sensor_3_R : 26.73
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -1226
HacR_VPM_LVDT:VALr : -803
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 23.3398
HacR_HPE1313A:0_Ch54 : -0.755859
HacR_alignROLL : -0.27362
HacR_alignPITCH : -0.0336898
HacR_alignHPT : -1.45307
HacL_HPM_LVDT:VALr : -7042
HacL_VPM_LVDT:VALr : 1758
HacL_HPE1313A:0_Ch58 : -0.148438
HacL_HPE1313A:0_Ch55 : 24.2676
HacL_HPE1313A:0_Ch54 : -0.149902
HacL_alignROLL : 0.2031
HacL_alignPITCH : -0.113184
HacL_alignHPT : 4.04127
Right Arm Angle Floor Angle : 18.5
Right Arm Angle Vernier : 59
Right Arm Scattering Angle : 19.0469
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6222
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 174
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88