User name adev
Log entry time 12:07:29 on October 12, 2000
Entry number 50178
Followups:
keyword=Start_Run_1768_Tar=4He-10cm,Type=pion_prod,Thcm=PY_2E,Pmom=1.931,Emom=1.8997,Ene=3.1704,Angle_e=24.787,Angle_h=18.622
Beginning-of-run EPICS data for Run Number 1768 at Thu Oct 12 12:07:21 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=800,ps2=2410,ps3=1800,ps4=150,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1428.49
Right Arm Q1 momentum : 1.89975
Right Arm Q1 gauss meter : 0.03594
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 817.662
Right Arm Q2 momentum : 1.89992
Right Arm Q2 gauss meter : -0.4304
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 657.008
Right Arm D1 momentum : 1.8997
Right Arm D1 NMR : 0.704956
Right Arm Q3 power supply current : 755.907
Right Arm Q3 momentum : 1.8997
Right Arm Q3 gauss meter : -0.339
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1452.74
Left Arm Q1 momentum : 1.93099
Left Arm Q1 gauss meter : -0.12302
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 831.347
Left Arm Q2 momentum : 1.93067
Left Arm Q2 gauss meter : 0.4389
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 653.323
Left Arm D1 momentum : 1.93101
Left Arm D1 NMR : 0.714554
Left Arm Q3 power supply current : 768.681
Left Arm Q3 momentum : 1.93078
Left Arm Q3 gauss meter : -0.3835
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0288032
Current on Unser monitor : 1.44621
Current on Upstream bcm : 0.0320476
Current on Downstream bcm : 0.0255588
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 88.9383
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : -44986
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.65
haSC200_6_Sensor_2_R : 229.84
haSC200_6_Sensor_3_R : 1.74
haSC200_6_Sensor_4_R : 36.78
haHe_Omega_DPG_Sensor_R : 5.733
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 5.88
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 234.4
haITC502_4_Sensor_3_R : 108.5
haITC502_5_Sensor_1_R : 6.1
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 191.8
haITC502_6_Sensor_1_R : 7.31
haITC502_6_Sensor_2_R : 6.03
haITC502_6_Sensor_3_R : 26.86
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -4203
HacR_VPM_LVDT:VALr : -817
HacR_HPE1313A:0_Ch58 : -0.540527
HacR_HPE1313A:0_Ch55 : 23.4863
HacR_HPE1313A:0_Ch54 : -0.72998
HacR_alignROLL : -0.247795
HacR_alignPITCH : -0.0177236
HacR_alignHPT : 1.83919
HacL_HPM_LVDT:VALr : -7065
HacL_VPM_LVDT:VALr : 1765
HacL_HPE1313A:0_Ch58 : -0.150391
HacL_HPE1313A:0_Ch55 : 24.4141
HacL_HPE1313A:0_Ch54 : -0.140137
HacL_alignROLL : 0.212675
HacL_alignPITCH : -0.111296
HacL_alignHPT : 4.05679
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 17.7
Right Arm Scattering Angle : 24.7866
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.622
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 400
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88