User name adev
Log entry time 01:27:40 on October 13, 2000
Entry number 50246
keyword=Start_Run_1796_Tar=4He-10cm,Type=pion_prod,Thcm=PY_2E,Pmom=1.931,Emom=1.8997,Ene=3.1704,Angle_e=24.787,Angle_h=18.622
Beginning-of-run EPICS data for Run Number 1796 at Fri Oct 13 01:27:30 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=800,ps2=2410,ps3=1800,ps4=150,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1428.53
Right Arm Q1 momentum : 1.8998
Right Arm Q1 gauss meter : 0.03594
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 817.604
Right Arm Q2 momentum : 1.89973
Right Arm Q2 gauss meter : -0.4304
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 657
Right Arm D1 momentum : 1.8997
Right Arm D1 NMR : 0.704955
Right Arm Q3 power supply current : 755.813
Right Arm Q3 momentum : 1.89946
Right Arm Q3 gauss meter : -0.339
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1452.74
Left Arm Q1 momentum : 1.93099
Left Arm Q1 gauss meter : -0.12301
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 831.518
Left Arm Q2 momentum : 1.93107
Left Arm Q2 gauss meter : 0.439
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 653.323
Left Arm D1 momentum : 1.931
Left Arm D1 NMR : 0.714553
Left Arm Q3 power supply current : 768.903
Left Arm Q3 momentum : 1.93134
Left Arm Q3 gauss meter : -0.3834
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 90.3165
Current on Unser monitor : 92.0763
Current on Upstream bcm : 90.1624
Current on Downstream bcm : 90.4705
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 90.0231
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.73
haSC200_6_Sensor_2_R : 234.45
haSC200_6_Sensor_3_R : 2.06
haSC200_6_Sensor_4_R : 36.83
haHe_Omega_DPG_Sensor_R : 5.781
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.1
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 239
haITC502_4_Sensor_3_R : 109.3
haITC502_5_Sensor_1_R : 6.19
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 187.3
haITC502_6_Sensor_1_R : 18.84
haITC502_6_Sensor_2_R : 6.33
haITC502_6_Sensor_3_R : 26.62
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -4204
HacR_VPM_LVDT:VALr : -806
HacR_HPE1313A:0_Ch58 : -0.539551
HacR_HPE1313A:0_Ch55 : 23.584
HacR_HPE1313A:0_Ch54 : -0.729492
HacR_alignROLL : -0.247121
HacR_alignPITCH : -0.0170246
HacR_alignHPT : 1.8388
HacL_HPM_LVDT:VALr : -7079
HacL_VPM_LVDT:VALr : 1762
HacL_HPE1313A:0_Ch58 : -0.150879
HacL_HPE1313A:0_Ch55 : 24.5117
HacL_HPE1313A:0_Ch54 : -0.140625
HacL_alignROLL : 0.211349
HacL_alignPITCH : -0.111733
HacL_alignHPT : 4.07195
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 17.7
Right Arm Scattering Angle : 24.7866
Left Arm Angle Floor Angle : 18.5
Left Arm Angle Vernier : 57
Left Arm Scattering Angle : 18.6219
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 435
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88