Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 11:11:33 on October 13, 2000
Entry number 50295
keyword=Start_Run_1817_Tar=4He-10cm,Type=Elastic,Pmom=3.14670,Emom=1.6270,Ene=3.166,Angle_e=32.522,Angle_h=14.07
Beginning-of-run EPICS data for Run Number 1817 at Fri Oct 13 11:11:24 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=340,ps2=940,ps3=16,ps4=80,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1223.46
Right Arm Q1 momentum : 1.62708
Right Arm Q1 gauss meter : 0.03084
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 700.321
Right Arm Q2 momentum : 1.62726
Right Arm Q2 gauss meter : -0.3687
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 558.4
Right Arm D1 momentum : 1.627
Right Arm D1 NMR : 0.603759
Right Arm Q3 power supply current : 647.555
Right Arm Q3 momentum : 1.62711
Right Arm Q3 gauss meter : -0.2904
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2367.57
Left Arm Q1 momentum : 3.14698
Left Arm Q1 gauss meter : -0.20048
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1354.91
Left Arm Q2 momentum : 3.14656
Left Arm Q2 gauss meter : 0.7142
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1106.54
Left Arm D1 momentum : 3.14671
Left Arm D1 NMR : 1.16528
Left Arm Q3 power supply current : 1252.49
Left Arm Q3 momentum : 3.14602
Left Arm Q3 gauss meter : -0.6248
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 69.3665
Current on Unser monitor : 70.1
Current on Upstream bcm : 69.2961
Current on Downstream bcm : 69.0068
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 69.3249
Beam energy : 3174.61
MBSY1c magnet current (amp) : 132.188
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.8
haSC200_6_Sensor_2_R : 233.75
haSC200_6_Sensor_3_R : 2.31
haSC200_6_Sensor_4_R : 36.92
haHe_Omega_DPG_Sensor_R : 5.673
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.78
haITC502_1_Sensor_3_R : 6.05
haITC502_4_Sensor_1_R : 6.2
haITC502_4_Sensor_2_R : 241.3
haITC502_4_Sensor_3_R : 110.1
haITC502_5_Sensor_1_R : 6.18
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 200.5
haITC502_6_Sensor_1_R : 7.52
haITC502_6_Sensor_2_R : 6.23
haITC502_6_Sensor_3_R : 26.78
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617188
HacR_HPM_LVDT:VALr : -4529
HacR_VPM_LVDT:VALr : -592
HacR_HPE1313A:0_Ch58 : -0.553711
HacR_HPE1313A:0_Ch55 : 23.584
HacR_HPE1313A:0_Ch54 : -0.73877
HacR_alignROLL : -0.256059
HacR_alignPITCH : -0.00662905
HacR_alignHPT : 2.20881
HacL_HPM_LVDT:VALr : -7451
HacL_VPM_LVDT:VALr : 1514
HacL_HPE1313A:0_Ch58 : -0.197266
HacL_HPE1313A:0_Ch55 : 24.5605
HacL_HPE1313A:0_Ch54 : 0.00976562
HacL_alignROLL : 0.352848
HacL_alignPITCH : -0.0908686
HacL_alignHPT : 4.42304
Right Arm Angle Floor Angle : 32
Right Arm Angle Vernier : 59
Right Arm Scattering Angle : 32.5221
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 48.4
Left Arm Scattering Angle : 14.07
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 333
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88