Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 09:35:44 on October 14, 2000
Entry number 50389
keyword=Start_Run_1847_Tar=4He-10cm,Type=pion_prod,Thcm=CQO-2A,Pmom=3.427,Emom=1.0409,Ene=3.9472,Angle_e=59.944,Angle_h=20.848
Beginning-of-run EPICS data for Run Number 1847 at Sat Oct 14 09:35:36 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=333,ps2=1300,ps3=21,ps4=40,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 782.705
Right Arm Q1 momentum : 1.04092
Right Arm Q1 gauss meter : 0.019868
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 448.055
Right Arm Q2 momentum : 1.0411
Right Arm Q2 gauss meter : -0.2363
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 355.296
Right Arm D1 momentum : 1.0409
Right Arm D1 NMR : 0.386265
Right Arm Q3 power supply current : 414.154
Right Arm Q3 momentum : 1.04083
Right Arm Q3 gauss meter : -0.18596
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2578.49
Left Arm Q1 momentum : 3.42733
Left Arm Q1 gauss meter : -0.21827
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1475.64
Left Arm Q2 momentum : 3.42693
Left Arm Q2 gauss meter : 0.7774
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1219.86
Left Arm D1 momentum : 3.42699
Left Arm D1 NMR : 1.26928
Left Arm Q3 power supply current : 1364.52
Left Arm Q3 momentum : 3.42752
Left Arm Q3 gauss meter : -0.6806
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 90.0218
Current on Unser monitor : 90.6338
Current on Upstream bcm : 89.9692
Current on Downstream bcm : 90.0233
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 89.3735
Beam energy : 3957.99
MBSY1c magnet current (amp) : 164.942
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 244
haSC200_6_Sensor_2_R : 234.83
haSC200_6_Sensor_3_R : 2.71
haSC200_6_Sensor_4_R : 37
haHe_Omega_DPG_Sensor_R : 5.739
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.1
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 245
haITC502_4_Sensor_3_R : 112
haITC502_5_Sensor_1_R : 6.23
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 191.4
haITC502_6_Sensor_1_R : 7.08
haITC502_6_Sensor_2_R : 6.65
haITC502_6_Sensor_3_R : 26.62
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -4921
HacR_VPM_LVDT:VALr : 279
HacR_HPE1313A:0_Ch58 : -0.498047
HacR_HPE1313A:0_Ch55 : 23.8281
HacR_HPE1313A:0_Ch54 : -0.760254
HacR_alignROLL : -0.277463
HacR_alignPITCH : -0.0559171
HacR_alignHPT : 2.56647
HacL_HPM_LVDT:VALr : -7057
HacL_VPM_LVDT:VALr : 2106
HacL_HPE1313A:0_Ch58 : -0.133301
HacL_HPE1313A:0_Ch55 : 24.8047
HacL_HPE1313A:0_Ch54 : -0.168945
HacL_alignROLL : 0.186669
HacL_alignPITCH : -0.127542
HacL_alignHPT : 4.06145
Right Arm Angle Floor Angle : 60
Right Arm Angle Vernier : -41
Right Arm Scattering Angle : 59.9433
Left Arm Angle Floor Angle : 21
Left Arm Angle Vernier : 9.5
Left Arm Scattering Angle : 20.8482
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 445
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88