User name adev
Log entry time 02:33:05 on October 15, 2000
Entry number 50432
keyword=End_of_Run_1863
****************************
Run Number: 1863
End of Run Comment:
Tar=4He-10cm,Type=pion_prod,Thcm=CQO-2A,Pmom=3.427,Emom=1.0409,Ene=3.9472,Angle_e=59.944,Angle_h=20.848
HV off at right spectr. at the end
Time of run = 7.1627117 min
Av. current (on 3x) = 87.48293 uA
Av. current (on 1x) = 87.296548 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 37.5168 | 37.5969 | 32.5549
up-down (mC)| 0.8201 | 0.7725 | 0.0831
Trigger | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 126801.3 /mC | 33.312 Hz | 4767335 | 333 | 127072.0 /mC
2 | 201799.2 /mC | 13.580 Hz | 7587025 | 1300 | 202230.1 /mC
3 | 17729.3 /mC | 73.858 Hz | 666566 | 21 | 17767.1 /mC
4 | 12961.3 /mC | 28.347 Hz | 487303 | 40 | 12988.9 /mC
5 | 136.9 /mC | 11.979 Hz | 5148 | 1 | 137.2 /mC
output 157.882 Hz
Av. deadtime from accepted triggers = 0.0198
Av. deadtime from gated scalers = 1.0000
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 0.0 Hz | 0.0 Hz | 11092.947 Hz
2 | 0.0 Hz | 0.0 Hz | 17653.987 Hz
3 | 1552.5256 Hz | 1549.1859 Hz | 1551.0094 Hz
4 | 1138.9634 Hz | 1127.7739 Hz | 1133.8885 Hz
5 | 0.0 Hz | 0.0 Hz | 11.978704 Hz
output | 0.0 Hz | 0.0 Hz | 157.882 Hz
Accepted triggers = 67852.00000
Time of run = 7.1627117 min
Time of run h- = 3.5410318 min
Time of run h+ = 3.540983 min
1-(sum of time hel + and -)/( run time) = 1.1266e-02
Rate of Left Arm Pulser for electronic DT = 10.17771
Rate of Right Arm Pulser for electronic DT = 10.17771
Rate of Left Arm Pulser&trig for electronic DT = 10.056713
Rate of Right Arm Pulser&trig for electronic DT = 10.119538
Left Arm Electronic DT = 0.011888432
Right Arm Electronic DT = 0.0057155921
Rate of Left Strobe = 110995.29
Rate of Right Arm Strobe = 49840.617
helicity | Gate on + and run | Gate on - and run | Gate on run
+ | 11.322528 Hz | 0.0 Hz | 11.324854 Hz
- | 0.0 Hz | 11.322528 Hz | 11.322528 Hz
Signal | Gate on + and run | Gate on - and run | Gate on run |
| Charge (C) | Charge (C) | Charge (C)
upstream | 0.0187833 | 0.0187153 | 0.0379269
upstream 3x | 0.0188102 | 0.0187439 | 0.0379832
upstream 10x| 0.0161261 | 0.0161015 | 0.0325965
downstream | 0.0183771 | 0.0183106 | 0.0371068
downstream 3x | 0.0184269 | 0.0183633 | 0.0372107
downstream 10x| 0.0160877 | 0.0160579 | 0.0325134
Signal | Asymmetry
|
upstream | -1.81340100e-03
upstream 3x | -1.76545300e-03
upstream 10x| -7.63320880e-04
downstream | -1.81259660e-03
downstream 3x | -1.72872120e-03
downstream 10x| -9.27032000e-04
****************************
End-of-run EPICS data for Run Number 1863 at Sun Oct 15 02:32:47 EDT 2000
Right Arm D1 momentum : 1.0409
Right Arm arm angle : 59.943
Left Arm D1 momentum : 3.42699
Left Arm arm angle : 20.8481
Tiefenbach Hall A energy : 3947.23
Right Arm arm mispointing (HPT) : 2.6089
Left Arm arm mispointing (HPT) : 4.08756
Right Arm Q1 power supply current : 782.705
Right Arm Q1 momentum : 1.04092
Right Arm Q1 gauss meter : 0.019857
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 448.113
Right Arm Q2 momentum : 1.04123
Right Arm Q2 gauss meter : -0.2363
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 355.297
Right Arm D1 momentum : 1.0409
Right Arm D1 NMR : 0.386265
Right Arm Q3 power supply current : 414.152
Right Arm Q3 momentum : 1.04082
Right Arm Q3 gauss meter : -0.18599
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2578.49
Left Arm Q1 momentum : 3.42733
Left Arm Q1 gauss meter : -0.21827
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1475.73
Left Arm Q2 momentum : 3.42715
Left Arm Q2 gauss meter : 0.7774
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1219.87
Left Arm D1 momentum : 3.42699
Left Arm D1 NMR : 1.26928
Left Arm Q3 power supply current : 1364.37
Left Arm Q3 momentum : 3.42704
Left Arm Q3 gauss meter : -0.6804
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 88.8631
Current on Unser monitor : 90.8229
Current on Upstream bcm : 89.1352
Current on Downstream bcm : 88.591
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 88.4115
MBSY1c Hall A Beam energy : 3957.99
MBSY1c magnet current (amp) : 164.942
MBSY1c Bdl : 987720
MBSY3c Hall C Beam energy : 2392.25
Tiefenbach Hall A energy : 3947.23
Tiefenbach Hall C energy : 2383.96
Delta(E)/E width (MV_AI_DXWID) : 2.4318
IPM1C12.XPOS : -0.0134041
IPM1H04A.XPOS : 0.664106
IPM1H04A.YPOS : 0.254098
IPM1H04B.XPOS : 0.00871785
IPM1H04B.YPOS : -0.0854498
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617236
HacR_HPM_LVDT:VALr : -4958
HacR_VPM_LVDT:VALr : 286
HacR_HPE1313A:0_Ch58 : -0.496582
HacR_HPE1313A:0_Ch55 : 23.9258
HacR_HPE1313A:0_Ch54 : -0.760742
HacR_alignROLL : -0.277285
HacR_alignPITCH : -0.0570175
HacR_alignHPT : 2.60855
HacL_HPM_LVDT:VALr : -7080
HacL_VPM_LVDT:VALr : 2130
HacL_HPE1313A:0_Ch58 : -0.132812
HacL_HPE1313A:0_Ch55 : 24.9023
HacL_HPE1313A:0_Ch54 : -0.168457
HacL_alignROLL : 0.186742
HacL_alignPITCH : -0.127616
HacL_alignHPT : 4.08935
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 61.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 36.62
haH2_P_Exhaust_R : 36.74
haH2_P_Fill_Bottle_R : 37.13
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R :
haD2_P_Exhaust_R : 0
haD2_P_Fill_Bottle_R : 0
haD2_DP_Fill_Exhaust_R : 27.388
haSC200_6_Sensor_1_R : 244.12
haSC200_6_Sensor_2_R : 234.73
haSC200_6_Sensor_3_R : 2.99
haSC200_6_Sensor_4_R : 37.1
haHe_Omega_DPG_Sensor_R : 5.703
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 6.11
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.3
haITC502_4_Sensor_2_R : 245.2
haITC502_4_Sensor_3_R : 111.6
haITC502_5_Sensor_1_R : 6.27
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 189.5
haITC502_6_Sensor_1_R : 7.19
haITC502_6_Sensor_2_R : 6.35
haITC502_6_Sensor_3_R : 26.6
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617236
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 470
Laser power Hall A : 63