    User name adev

    Log entry time 09:21:37 on October 20, 2000

    Entry number 50634

    keyword=End_of_Run_1944
    ****************************
     Run Number: 1944
    End of Run Comment:
    Tar=4He-10cm,Type=QuasiElastic,Pmom=3.427,Emom=1.0409,Ene=3.9472,Angle_e=68.297,Angle_h=20.848
    Good data, Beam going away for injector work estimate 2 hours down.
    
    
    Time of run = 14.972477 min
    Av. current (on 3x) = 68.556235 uA
    Av. current (on 1x) = 68.39672 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   61.4441  |   61.5874  |   55.1645
    up-down    (mC)|    1.2498  |    1.1693  |    0.4977
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |    101138.6 /mC  |   57.781 Hz  |   6228866  |   120   |    101374.5 /mC
        2      |    375764.9 /mC  |   24.770 Hz  |  23142384  |  1040   |    376641.3 /mC
        3      |     17492.2 /mC  |   59.960 Hz  |   1077301  |    20   |     17533.0 /mC
        4      |     12001.7 /mC  |   22.238 Hz  |    739155  |    37   |     12029.7 /mC
        5      |       160.9 /mC  |   11.030 Hz  |      9909  |     1   |       161.3 /mC
        output                       171.693 Hz
    Av. deadtime from accepted triggers = 0.0232
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  0.0  Hz     |    0.0 Hz   |  6933.6845 Hz
        2      |  0.0  Hz     |    0.0 Hz   |  25761.028 Hz
        3      |  1196.839  Hz     |    1201.293 Hz   |  1199.2015 Hz
        4      |  817.72213  Hz     |    827.52723 Hz   |  822.79304 Hz
        5      |  0.0  Hz     |    0.0 Hz   |  11.030239 Hz
        output |  0.0  Hz   |    0.0 Hz |   171.693 Hz
    Accepted triggers  = 154240.00000
     Time of run = 14.972477 min
     Time of run h- = 7.4010253 min
     Time of run h+ = 7.4025553 min
     1-(sum of time hel + and -)/( run time) = 1.1280e-02
    Rate of Left Arm Pulser for electronic DT  = 10.173111
    Rate of Right Arm Pulser for electronic DT  = 10.173111
    Rate of Left Arm Pulser&trig for electronic DT  = 10.081832
    Rate of Right Arm Pulser&trig for electronic DT  = 10.127471
    Left Arm Electronic DT  = 0.0089725353
    Right Arm Electronic DT  = 0.0044862676
    Rate of Left Strobe  = 84013.363
    Rate of Right Arm Strobe  = 50734.293
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.268454  Hz         |    0.0 Hz        |  11.268454 Hz
          -        |  0.0  Hz        |    11.267341 Hz       |  11.268454 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0306073         |   0.0307607         | 0.0620690     
       upstream 3x |   0.0306600         |   0.0308096         | 0.0621721     
       upstream 10x|   0.0273599         |   0.0274283         | 0.0554133     
      downstream   |   0.0299910         |   0.0301413         | 0.0608192    
     downstream 3x |   0.0300849         |   0.0302287         | 0.0610028    
     downstream 10x|   0.0271072         |   0.0271887         | 0.0549156    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   2.49967410e-03 
       upstream 3x |   2.43372330e-03 
       upstream 10x|   1.24844400e-03 
      downstream   |   2.49948860e-03 
     downstream 3x |   2.38420520e-03 
     downstream 10x|   1.50103410e-03 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1944 at Fri Oct 20 09:21:27 EDT 2000
    Right Arm D1 momentum                    : 1.0409
    Right Arm arm angle                      : 68.2964
    Left Arm D1 momentum                      : 3.427
    Left Arm arm angle                        : 20.8488
    Tiefenbach Hall A energy                : 3947.23
    Right Arm arm mispointing (HPT)          : 2.17216
    Left Arm arm mispointing (HPT)            : 3.98469
    Right Arm Q1 power supply current        : 782.74
    Right Arm Q1 momentum                    : 1.04097
    Right Arm Q1 gauss meter                 : 0.019816
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 448.111
    Right Arm Q2 momentum                    : 1.04123
    Right Arm Q2 gauss meter                 : -0.2363
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 355.291
    Right Arm D1 momentum                    : 1.0409
    Right Arm D1 NMR                         : 0.386265
    Right Arm Q3 power supply current        : 414.238
    Right Arm Q3 momentum                    : 1.04104
    Right Arm Q3 gauss meter                 : -0.18594
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 2578.42
    Left Arm Q1 momentum                      : 3.42723
    Left Arm Q1 gauss meter                   : -0.21829
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1475.64
    Left Arm Q2 momentum                      : 3.42695
    Left Arm Q2 gauss meter                   : 0.7774
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 1220.28
    Left Arm D1 momentum                      : 3.427
    Left Arm D1 NMR                           : 1.26929
    Left Arm Q3 power supply current          : 1364.35
    Left Arm Q3 momentum                      : 3.427
    Left Arm Q3 gauss meter                   : -0.6805
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 0.0292128
    Current on Unser monitor                : 0.429273
    Current on Upstream bcm                 : 0.0292402
    Current on Downstream bcm               : 0.0291994
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 0.00142881
    MBSY1c Hall A Beam energy               : 3957.99
    MBSY1c magnet current (amp)             : 164.942
    MBSY1c Bdl                              : 987720
    MBSY3c Hall C Beam energy               : 826.736
    Tiefenbach Hall A energy                : 3947.23
    Tiefenbach Hall C energy                : 824.654
    Delta(E)/E width (MV_AI_DXWID)          : 1.48481
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617188
     HacR_HPM_LVDT:VALr                     : -4600
     HacR_VPM_LVDT:VALr                     : 1088
     HacR_HPE1313A:0_Ch58                   : -0.48877
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.713379
     HacR_alignROLL                         : -0.231633
     HacR_alignPITCH                        : -0.0633026
     HacR_alignHPT                          : 2.17244
     HacL_HPM_LVDT:VALr                     : -6982
     HacL_VPM_LVDT:VALr                     : 2625
     HacL_HPE1313A:0_Ch58                   : -0.128906
     HacL_HPE1313A:0_Ch55                   : 24.4141
     HacL_HPE1313A:0_Ch54                   : -0.174805
     HacL_alignROLL                         : 0.180855
     HacL_alignPITCH                        : -0.130516
     HacL_alignHPT                          : 3.98267
    haBDSPOS                                 : 6.517e+06
    haL1_Fan_frequency_R                     : 61.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 34.36
    haH2_P_Exhaust_R                         : 34.52
    haH2_P_Fill_Bottle_R                     : 34.89
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.413
    haSC200_6_Sensor_1_R                     : 242.68
    haSC200_6_Sensor_2_R                     : 214.01
    haSC200_6_Sensor_3_R                     : 3.31
    haSC200_6_Sensor_4_R                     : 37.4
    haHe_Omega_DPG_Sensor_R                  : 5.975
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.8
    haITC502_1_Sensor_3_R                    : 5.89
    haITC502_2_Sensor_1_R                    : 94.98
    haITC502_2_Sensor_2_R                    : 94.98
    haITC502_2_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 174
    haITC502_4_Sensor_3_R                    : 101.8
    haITC502_5_Sensor_1_R                    : 6.25
    haITC502_5_Sensor_2_R                    : 5.81
    haITC502_5_Sensor_3_R                    : 187.4
    haITC502_6_Sensor_1_R                    : 12.54
    haITC502_6_Sensor_2_R                    : 6.55
    haITC502_6_Sensor_3_R                    : 26.2
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617188
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 345
    Laser power  Hall A                      : 63